Design Technical Manual
Table Of Contents
- CHAPTER00
- CHAPTER01_General_information
- CHAPTER02_Model_selection
- 1. MODEL SELECTION PROCEDURE
- 2. MODEL LINE UP
- 3. MODEL SELECTION AND CAPACITY CALCULATION
- 4. CAPACITY TABLE COOLING (OUTDOOR UNIT)
- 5. CAPACITY TABLE HEATING (OUTDOOR UNIT)
- 6. CAPACITY COMPENSATION COEFFICIENT
- 7. CAPACITY TABLE COOLING (INDOOR UNIT)
- 7-1. COMPACT CASSETTE TYPE
- 7-2. CIRCULAR FLOW CASSETTE TYPE
- 7-3. CASSETTE TYPE
- 7-4. MINI DUCT TYPE
- 7-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 7-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 7-7. HIGH STATIC PRESSURE DUCT TYPE
- 7-8. VERTICAL AIR HANDLER TYPE
- 7-9. COMPACT FLOOR TYPE
- 7-10. FLOOR / CEILING TYPE
- 7-11. CEILING TYPE
- 7-12. WALL MOUNTED TYPE
- 8. CAPACITY TABLE HEATING (INDOOR UNIT)
- 8-1. COMPACT CASSETTE TYPE
- 8-2. CIRCULAR FLOW CASSETTE TYPE
- 8-3. CASSETTE TYPE
- 8-4. MINI DUCT TYPE
- 8-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 8-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 8-7. HIGH STATIC PRESSURE DUCT TYPE
- 8-8. VERTICAL AIR HANDLER TYPE
- 8-9. COMPACT FLOOR TYPE
- 8-10. FLOOR / CEILING TYPE
- 8-11. CEILING TYPE
- 8-12. WALL MOUNTED TYPE
- CHAPTER03_Outdoor_units
- CHAPTER04_Indoor_units
- CHAPTER05_Control_system
- 1. CONTROL SYSTEM
- 2. CONTROL UNITS
- 2-1. SYSTEM CONTROLLER
- 2-2. SYSTEM CONTROLLER LITE
- 2-3. TOUCH PANEL CONTROLLER
- 2-4. CENTRAL REMOTE CONTROLLER
- 2-5. WIRED REMOTE CONTROLLER (Touch panel)
- 2-6. WIRED REMOTE CONTROLLER
- 2-7. SIMPLE REMOTE CONTROLLER (With Operation mode)
- 2-8. SIMPLE REMOTE CONTROLLER (Without Operation mode)
- 2-9. WIRELESS REMOTE CONTROLLER
- 2-10. IR RECEIVER UNIT (for ALL DUCT TYPE)
- 2-11. IR RECEIVER UNIT (for CASSETTE TYPE)
- 2-12. IR RECEIVER UNIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-13. HUMAN SENSOR KIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-14. REMOTE SENSOR UNIT
- 2-15. PRESSURE SENSOR KIT
- 2-16. GROUP CONTROL METHOD
- 2-17. COMPARISON TABLE OF CONTROLLERS
- 3. ADAPTOR / CONVERTOR UNITS
- 4. SERVICE & WEB MONITORING TOOL
- CHAPTER06_System_design
- CHAPTER07_Function_setting
- CHAPTER08_External_input_and_output
- CHAPTER09_Notes
- CHAPTER10_Optional_parts
- CHAPTER99
Case2 : When setting number is two digits.
(11-2) Indoor unit will display the function setting number on "OPERATION"(GREEN), "TIMER
"(ORANGE) and "FILTER "(RED) light.
OPERATION
(GREEN)
TIMER
(ORANGE)
Flashing times of
function numbers
(the ten’s place)
FILTER
(RED)
Flashing times of
function numbers
(the one’s place)
Flashing times of
setting numbers
(the one’s place)
OPERATION
(GREEN)
TIMER
(ORANGE)
OFF OFF
FILTER
(RED)
Flashing times of
setting numbers
(the ten’s place)
(Example) Function number : 26, Setting number : 31
OPERATION LAMP
(GREEN)
TIMER LAMP
(ORANGE)
FILTER L AMP
(RED)
0.5sec ON / 0.5sec OFF
0.5sec ON / 0.5sec OFF
OFF
OFF
1 time
3 times
2 times
6 times
...
...
...
(Phase1) : 12sec (Phase2) : 12sec
0.5sec ON / 0.5sec OFF 0.5sec ON / 0.5sec OFF
Phase1
The display of "Phase1" and
"Phase2" is alternately repeated.
Phase2
¾
Number 0 setting will not indicate TIMER LAMP and FILTER LAMP.
z
Conrmation of function setting
(12) Press the “TIMER set (+)” button.
“TIMER set (+)”
PiPi
CORRECT : Pi PiPiPiPiPi
PiPi
WRONG: Pi (3 sec)
FUNCTION DETAILS
Refer to 2-8. FUNCTION DETAILS.
- (07 - 101) -
FUNCTION
SETTING
FUNCTION
SETTING