Design Technical Manual
Table Of Contents
- CHAPTER00
- CHAPTER01_General_information
- CHAPTER02_Model_selection
- 1. MODEL SELECTION PROCEDURE
- 2. MODEL LINE UP
- 3. MODEL SELECTION AND CAPACITY CALCULATION
- 4. CAPACITY TABLE COOLING (OUTDOOR UNIT)
- 5. CAPACITY TABLE HEATING (OUTDOOR UNIT)
- 6. CAPACITY COMPENSATION COEFFICIENT
- 7. CAPACITY TABLE COOLING (INDOOR UNIT)
- 7-1. COMPACT CASSETTE TYPE
- 7-2. CIRCULAR FLOW CASSETTE TYPE
- 7-3. CASSETTE TYPE
- 7-4. MINI DUCT TYPE
- 7-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 7-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 7-7. HIGH STATIC PRESSURE DUCT TYPE
- 7-8. VERTICAL AIR HANDLER TYPE
- 7-9. COMPACT FLOOR TYPE
- 7-10. FLOOR / CEILING TYPE
- 7-11. CEILING TYPE
- 7-12. WALL MOUNTED TYPE
- 8. CAPACITY TABLE HEATING (INDOOR UNIT)
- 8-1. COMPACT CASSETTE TYPE
- 8-2. CIRCULAR FLOW CASSETTE TYPE
- 8-3. CASSETTE TYPE
- 8-4. MINI DUCT TYPE
- 8-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 8-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 8-7. HIGH STATIC PRESSURE DUCT TYPE
- 8-8. VERTICAL AIR HANDLER TYPE
- 8-9. COMPACT FLOOR TYPE
- 8-10. FLOOR / CEILING TYPE
- 8-11. CEILING TYPE
- 8-12. WALL MOUNTED TYPE
- CHAPTER03_Outdoor_units
- CHAPTER04_Indoor_units
- CHAPTER05_Control_system
- 1. CONTROL SYSTEM
- 2. CONTROL UNITS
- 2-1. SYSTEM CONTROLLER
- 2-2. SYSTEM CONTROLLER LITE
- 2-3. TOUCH PANEL CONTROLLER
- 2-4. CENTRAL REMOTE CONTROLLER
- 2-5. WIRED REMOTE CONTROLLER (Touch panel)
- 2-6. WIRED REMOTE CONTROLLER
- 2-7. SIMPLE REMOTE CONTROLLER (With Operation mode)
- 2-8. SIMPLE REMOTE CONTROLLER (Without Operation mode)
- 2-9. WIRELESS REMOTE CONTROLLER
- 2-10. IR RECEIVER UNIT (for ALL DUCT TYPE)
- 2-11. IR RECEIVER UNIT (for CASSETTE TYPE)
- 2-12. IR RECEIVER UNIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-13. HUMAN SENSOR KIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-14. REMOTE SENSOR UNIT
- 2-15. PRESSURE SENSOR KIT
- 2-16. GROUP CONTROL METHOD
- 2-17. COMPARISON TABLE OF CONTROLLERS
- 3. ADAPTOR / CONVERTOR UNITS
- 4. SERVICE & WEB MONITORING TOOL
- CHAPTER06_System_design
- CHAPTER07_Function_setting
- CHAPTER08_External_input_and_output
- CHAPTER09_Notes
- CHAPTER10_Optional_parts
- CHAPTER99
ADDRESS SETTING
z
INDOOR UNIT ADDRESS SETTING
(7) Press the “MODE” button to access the
address setting mode.
(8) Make sure the function number is ‘01’. If the
number is other than ‘01’, press the “
p
” or
the “
q
” buttons to alter.
(9) Press the “FAN” button to access the
address data setting mode. The address
data will ash once this button is pressed.
Address data
(10) Press the “
p
” or the “
q
” buttons to
adjust the address data. The indoor unit
address range is between 00 and 63.
Each time the “MODE” button is pressed, it
switches between the one' place and the ten's
place positions.
Range
00 - 63
: UP
: DOWN
Change digit
(11) Press the “START/STOP” button once to
send the information. A beeping noise will
be heard if the command is accepted.
Pi Pi
Pi PiPiPi
¾
In the following cases the setting signal is not read
and a buzzer sounds.
The indoor unit address No. is set out of range
(64 or more) : Pi Pi Pi Pi Pi
The setting of the rotary switch on the PCB is not
"00" : Pi Pi Pi Pi Pi
(12) Indoor unit will display the indoor unit
address data number on "TIMER
"(ORANGE) and "FILTER "(RED) light.
OPERATION
(GREEN)
TIMER
(ORANGE)
continuously Flashing times of
address numbers
(the ten’s place)
FILTER
(RED)
Flashing times of
address numbers
(the one’s place)
(Example) ADDRESS : 34
OPERATION LAMP
(GREEN)
TIMER LAMP
(ORANGE)
FILTER L AMP
(RED)
0.5sec ON / 0.5sec OFF
4 times
3 times 1 - 10 sec
1 - 10 sec
0.5sec ON / 0.5sec OFF
¾
ADDRESS 0 setting will not indicate TIMER LAMP
and FILTER LAMP.
z
Conrmation of address setting
(13) Press the “TIMER set (+)” button.
“TIMER set (+)”
PiPi
CORRECT : Pi PiPiPiPiPi
PiPi
WRONG: Pi (3 sec)
SET "01"
- (07 - 19) -
FUNCTION
SETTING
FUNCTION
SETTING