Design Technical Manual
Table Of Contents
- CHAPTER00
- CHAPTER01_General_information
- CHAPTER02_Model_selection
- 1. MODEL SELECTION PROCEDURE
- 2. MODEL LINE UP
- 3. MODEL SELECTION AND CAPACITY CALCULATION
- 4. CAPACITY TABLE COOLING (OUTDOOR UNIT)
- 5. CAPACITY TABLE HEATING (OUTDOOR UNIT)
- 6. CAPACITY COMPENSATION COEFFICIENT
- 7. CAPACITY TABLE COOLING (INDOOR UNIT)
- 7-1. COMPACT CASSETTE TYPE
- 7-2. CIRCULAR FLOW CASSETTE TYPE
- 7-3. CASSETTE TYPE
- 7-4. MINI DUCT TYPE
- 7-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 7-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 7-7. HIGH STATIC PRESSURE DUCT TYPE
- 7-8. VERTICAL AIR HANDLER TYPE
- 7-9. COMPACT FLOOR TYPE
- 7-10. FLOOR / CEILING TYPE
- 7-11. CEILING TYPE
- 7-12. WALL MOUNTED TYPE
- 8. CAPACITY TABLE HEATING (INDOOR UNIT)
- 8-1. COMPACT CASSETTE TYPE
- 8-2. CIRCULAR FLOW CASSETTE TYPE
- 8-3. CASSETTE TYPE
- 8-4. MINI DUCT TYPE
- 8-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 8-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 8-7. HIGH STATIC PRESSURE DUCT TYPE
- 8-8. VERTICAL AIR HANDLER TYPE
- 8-9. COMPACT FLOOR TYPE
- 8-10. FLOOR / CEILING TYPE
- 8-11. CEILING TYPE
- 8-12. WALL MOUNTED TYPE
- CHAPTER03_Outdoor_units
- CHAPTER04_Indoor_units
- CHAPTER05_Control_system
- 1. CONTROL SYSTEM
- 2. CONTROL UNITS
- 2-1. SYSTEM CONTROLLER
- 2-2. SYSTEM CONTROLLER LITE
- 2-3. TOUCH PANEL CONTROLLER
- 2-4. CENTRAL REMOTE CONTROLLER
- 2-5. WIRED REMOTE CONTROLLER (Touch panel)
- 2-6. WIRED REMOTE CONTROLLER
- 2-7. SIMPLE REMOTE CONTROLLER (With Operation mode)
- 2-8. SIMPLE REMOTE CONTROLLER (Without Operation mode)
- 2-9. WIRELESS REMOTE CONTROLLER
- 2-10. IR RECEIVER UNIT (for ALL DUCT TYPE)
- 2-11. IR RECEIVER UNIT (for CASSETTE TYPE)
- 2-12. IR RECEIVER UNIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-13. HUMAN SENSOR KIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-14. REMOTE SENSOR UNIT
- 2-15. PRESSURE SENSOR KIT
- 2-16. GROUP CONTROL METHOD
- 2-17. COMPARISON TABLE OF CONTROLLERS
- 3. ADAPTOR / CONVERTOR UNITS
- 4. SERVICE & WEB MONITORING TOOL
- CHAPTER06_System_design
- CHAPTER07_Function_setting
- CHAPTER08_External_input_and_output
- CHAPTER09_Notes
- CHAPTER10_Optional_parts
- CHAPTER99
INSTALLATION CONDITION OF SIGNAL AMPLIFIER
To ensure proper communication in a VRF Network, the following conditions must be met:
●
Wiring length
Total transmission line length: Maximum 1640 ft. (500 m).
Transmission line length between each unit: Maximum 1312 ft. (400 m).
●
Number of element
The number of total element in 1 segment: Maximum 64 elements.
(Number of elements as dened in the table below)
z
Meaning of element
Each units below should be counted in Segment
Model name Count
Outdoor unit
Master -
1
Slave -
0
All indoor unit -
1
RB unit
Single type
UTP-RU01AH
UTP-RU01BH
UTP-RU01CH
1
Multi type UTP-RU04BH *1
4
Controller
System controller UTY-APGX Z1
1
System controller Lite UTY-ALGXZ1 *1
1
Touch panel controller UT Y-DTG
Z1
1
Central Remote controller UTY-DCG
1
Group remote controller UT Y- CGG
0
Wired remote controller (Touch panel) UTY-RNRUZ2
0
Wired remote controller UTY- RNK
0
Simple remote controller (With operation mode) UTY-RSRY, UTY-RSKU
0
Simple remote controller (Without operation mode) UT Y- RHRY, UT Y- RHKU
0
Wireless remote controller UTY-LNH
0
IR receiver unit for Duct UTB-
WC
0
IR receiver unit for Cassette
UT Y- LRHYB1
UTY-LBHXD
0
Adaptor /
Convertor
External switch controller UTY-TERX, UTY-TEKX
0
Network convertor UT Y-V TGX, UTY-VGGXZ1
1
Network convertor for L
ON
W
ORKS
®
UT Y-VLGX
1
Modbus
®
convertor for VRF UTY-VMGX
1
BACnet
®
Gateway (Hardware) UTY-VBGX
1
BACnet
®
Gateway (Software) UT Y-ABGXZ1
1
Signal amplier UT Y-VSGX Z1 *1
1
Maintenance
Service tool UTY-ASGXZ1
1
Web monitoring tool UTY-AMGXZ1
1
Option Others optional parts -
0
*1: Signal Amplier and RB unit should count each Segment.
- (06 - 104) -
SYSTEM
DESIGN
SYSTEM
DESIGN