Design Technical Manual
Table Of Contents
- CHAPTER00
- CHAPTER01_General_information
- CHAPTER02_Model_selection
- 1. MODEL SELECTION PROCEDURE
- 2. MODEL LINE UP
- 3. MODEL SELECTION AND CAPACITY CALCULATION
- 4. CAPACITY TABLE COOLING (OUTDOOR UNIT)
- 5. CAPACITY TABLE HEATING (OUTDOOR UNIT)
- 6. CAPACITY COMPENSATION COEFFICIENT
- 7. CAPACITY TABLE COOLING (INDOOR UNIT)
- 7-1. COMPACT CASSETTE TYPE
- 7-2. CIRCULAR FLOW CASSETTE TYPE
- 7-3. CASSETTE TYPE
- 7-4. MINI DUCT TYPE
- 7-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 7-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 7-7. HIGH STATIC PRESSURE DUCT TYPE
- 7-8. VERTICAL AIR HANDLER TYPE
- 7-9. COMPACT FLOOR TYPE
- 7-10. FLOOR / CEILING TYPE
- 7-11. CEILING TYPE
- 7-12. WALL MOUNTED TYPE
- 8. CAPACITY TABLE HEATING (INDOOR UNIT)
- 8-1. COMPACT CASSETTE TYPE
- 8-2. CIRCULAR FLOW CASSETTE TYPE
- 8-3. CASSETTE TYPE
- 8-4. MINI DUCT TYPE
- 8-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 8-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 8-7. HIGH STATIC PRESSURE DUCT TYPE
- 8-8. VERTICAL AIR HANDLER TYPE
- 8-9. COMPACT FLOOR TYPE
- 8-10. FLOOR / CEILING TYPE
- 8-11. CEILING TYPE
- 8-12. WALL MOUNTED TYPE
- CHAPTER03_Outdoor_units
- CHAPTER04_Indoor_units
- CHAPTER05_Control_system
- 1. CONTROL SYSTEM
- 2. CONTROL UNITS
- 2-1. SYSTEM CONTROLLER
- 2-2. SYSTEM CONTROLLER LITE
- 2-3. TOUCH PANEL CONTROLLER
- 2-4. CENTRAL REMOTE CONTROLLER
- 2-5. WIRED REMOTE CONTROLLER (Touch panel)
- 2-6. WIRED REMOTE CONTROLLER
- 2-7. SIMPLE REMOTE CONTROLLER (With Operation mode)
- 2-8. SIMPLE REMOTE CONTROLLER (Without Operation mode)
- 2-9. WIRELESS REMOTE CONTROLLER
- 2-10. IR RECEIVER UNIT (for ALL DUCT TYPE)
- 2-11. IR RECEIVER UNIT (for CASSETTE TYPE)
- 2-12. IR RECEIVER UNIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-13. HUMAN SENSOR KIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-14. REMOTE SENSOR UNIT
- 2-15. PRESSURE SENSOR KIT
- 2-16. GROUP CONTROL METHOD
- 2-17. COMPARISON TABLE OF CONTROLLERS
- 3. ADAPTOR / CONVERTOR UNITS
- 4. SERVICE & WEB MONITORING TOOL
- CHAPTER06_System_design
- CHAPTER07_Function_setting
- CHAPTER08_External_input_and_output
- CHAPTER09_Notes
- CHAPTER10_Optional_parts
- CHAPTER99
WIRING SPECIFICATIONS
Use Size Wire type Remarks
Power supply cable
Maximum
16 AWG
(1.25 mm
2
)
245 IEC 57 or equivalent
1 ø AC100 - 240 V 50/60 Hz,
2 Wire + ground
(Always ground the unit)
Minimum
20 AWG
(0.5 mm
2
)
Transmission cable
22AWG
(0.33
mm
2
)
LEVEL4 (NEMA) non-polar 2
core, twisted pair solid core
Shielded
L
ON
W
ORKS
®
compatible cable
External input /
output cable
22AWG
(0.33
mm
2
)
Polar 2core, Twisted pair
Use cable in accordance
with local rules for cable.
Fuse capacity 5 A
SPECIFICATIONS
Power source voltage (V)
1 ø AC 100 - 240
Power source frequency (Hz)
50 / 60
Input Power (W)
22
Display
7.5-inch TFT color LCD display (640 × 480 pixels), with Touch panel
LED indicator
Power LED (Green)
External interface
USB 2.0
Transmission line
Ethernet port *
1
(Ethernet port is required for remote connection using internet.)
EXT IN: (Either emergency stop or batch operation/stop,
Electricity meter *
1
)
(Either Dry contact or Apply voltage can be selected)
EXT OUT: (Operation state, error state)
Reset SW
Usage temperature range: °F (°C)
32 to 104 (0 to 40)
Usage humidity range (%)
0 to 85 (no condensation)
Storage temperature range: °F (°C)
-4 to 158 (-20 to 70)
Storage humidity range (%)
0 to 85 (no condensation)
Dimensions [H × W × D]: in. (mm)
10-1/4
×
9-11/16
×
2-1/8 (260
×
246
×
54)
Weight: lbs. (g)
5 (2,150)
*
1
: Only for UTY-DTGYZ1
- (05 - 47) -
CONTROL
SYSTEM
CONTROL
SYSTEM