Design Technical Manual
Table Of Contents
- CHAPTER00
- CHAPTER01_General_information
- CHAPTER02_Model_selection
- 1. MODEL SELECTION PROCEDURE
- 2. MODEL LINE UP
- 3. MODEL SELECTION AND CAPACITY CALCULATION
- 4. CAPACITY TABLE COOLING (OUTDOOR UNIT)
- 5. CAPACITY TABLE HEATING (OUTDOOR UNIT)
- 6. CAPACITY COMPENSATION COEFFICIENT
- 7. CAPACITY TABLE COOLING (INDOOR UNIT)
- 7-1. COMPACT CASSETTE TYPE
- 7-2. CIRCULAR FLOW CASSETTE TYPE
- 7-3. CASSETTE TYPE
- 7-4. MINI DUCT TYPE
- 7-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 7-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 7-7. HIGH STATIC PRESSURE DUCT TYPE
- 7-8. VERTICAL AIR HANDLER TYPE
- 7-9. COMPACT FLOOR TYPE
- 7-10. FLOOR / CEILING TYPE
- 7-11. CEILING TYPE
- 7-12. WALL MOUNTED TYPE
- 8. CAPACITY TABLE HEATING (INDOOR UNIT)
- 8-1. COMPACT CASSETTE TYPE
- 8-2. CIRCULAR FLOW CASSETTE TYPE
- 8-3. CASSETTE TYPE
- 8-4. MINI DUCT TYPE
- 8-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 8-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 8-7. HIGH STATIC PRESSURE DUCT TYPE
- 8-8. VERTICAL AIR HANDLER TYPE
- 8-9. COMPACT FLOOR TYPE
- 8-10. FLOOR / CEILING TYPE
- 8-11. CEILING TYPE
- 8-12. WALL MOUNTED TYPE
- CHAPTER03_Outdoor_units
- CHAPTER04_Indoor_units
- CHAPTER05_Control_system
- 1. CONTROL SYSTEM
- 2. CONTROL UNITS
- 2-1. SYSTEM CONTROLLER
- 2-2. SYSTEM CONTROLLER LITE
- 2-3. TOUCH PANEL CONTROLLER
- 2-4. CENTRAL REMOTE CONTROLLER
- 2-5. WIRED REMOTE CONTROLLER (Touch panel)
- 2-6. WIRED REMOTE CONTROLLER
- 2-7. SIMPLE REMOTE CONTROLLER (With Operation mode)
- 2-8. SIMPLE REMOTE CONTROLLER (Without Operation mode)
- 2-9. WIRELESS REMOTE CONTROLLER
- 2-10. IR RECEIVER UNIT (for ALL DUCT TYPE)
- 2-11. IR RECEIVER UNIT (for CASSETTE TYPE)
- 2-12. IR RECEIVER UNIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-13. HUMAN SENSOR KIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-14. REMOTE SENSOR UNIT
- 2-15. PRESSURE SENSOR KIT
- 2-16. GROUP CONTROL METHOD
- 2-17. COMPARISON TABLE OF CONTROLLERS
- 3. ADAPTOR / CONVERTOR UNITS
- 4. SERVICE & WEB MONITORING TOOL
- CHAPTER06_System_design
- CHAPTER07_Function_setting
- CHAPTER08_External_input_and_output
- CHAPTER09_Notes
- CHAPTER10_Optional_parts
- CHAPTER99
FUNCTIONS
z
MODEL: UTY-DTGYZ1
Item
Main unit PC / Tablet
Description
Installation
Indoor unit registration
z
Indoor unit registration. Max. 400 units.
(Set data can be written to and read from USB ash drive)
Functions setting
z
Temperature set point limitation, external input, central
operation on/o setting.
Monitor
Display switching
z z
Icon display, list display
Display units
z z
ALL, group, individual (remote control group)
Monitor contents (icon
display)
z z
Group name, operation, operation mode, set temperature,
time, errors, timer setting, lter sign, room temp., human
sensor, set temp. range
Monitor contents (list
display)
z z
Group name, operation, operation mode, set temperature,
airow, air direction, special operation, anti-freeze, time,
errors, timer setting, lter sign
Error list
z z
Group name, remote control group name, address, error code
Special state
z z
Display during special operation
Control
Control units
z z
ALL, group, individual (remote control group)
Control contents
z z
Operation, operation mode, set temperature, airow,
RC Prohibition, lter sign reset
Detailed control contents
z z
Air direction, energy saving, anti-freeze, test run
Individual setting reset of
airow direction
z
Sets the position of indoor unit's airow direction louver
individually.
Human sensor
z
Sets the human sensor on the indoor unit.
Setting temperature
limitation of room
z z
Adjusts the upper and lower limits of temperature for the
indoor unit.
Setting
Language setting
z z
Design considering multi-language correspondence. *
1
Date and time
z z
Time display switching, year/month/day display switching,
system clock setting, summer time, internet time adjustment
setting
Time zone
z z
Set the time zone of the area where this unit is used
Panel cleaning and
correction
z
Select display area for panel cleaning.
User can select black screen on display.
Group
z z
Stages: Max. 3 stages Settable up to 400 groups.
(Set data can be written to and read from USB ash drive)
Background light and
beep sound
z
Backlighting o time and brightness setting, BEEP sound
operation setting
Password
z
Management level: 3 kinds
Schedule timer
z z
Max. 30 items settable
Temperature range
z
Celsius/Fahrenheit switching, cooling, heating, and AUTO
each settable.
Network
z z
function of Email notication for malfunction, or electricity
charge apportionment option is used via LAN
Low noise operation
z z
"Low noise operation" is set to all the outdoor units registered
by this controller.
Electricity charge
apportionment
*
2
z z
Start/stop of ECA, importing/exporting of ECA setting, and
exporting ECA data.
Remote language
additional registration
z
Additional language can be integrated on remote device by
creating language database.
Additional language is displayed on only the remote device
and touch panel controller cannot be added other language.
Auto OFF timer
z
Function to stop the operation automatically when a preset
time lapses after turning on the operation.
Set temperature auto
return
z
Function to restore the temperature to the original set
temperature when a preset time lapses after changing the set
temperature.
Display item setting
z
Sets the items to be displayed on the monitor.
Failure notication Email
z
Failure notication Email: Sends a notication Email to the
preset Email address in the event of failure.
Remote connection
setting
z
Create users: Max. 15 users, type, permissions, unit setting,
automatic logout time
Maintenance
Error history
z z
Recording of Max. 10 errors each for touch panel controller
and each unit (indoor unit, outdoor unit)
Status history
z z
Recording of Max. 100 operations each for each indoor unit.
Writable to USB ash drive.
Operation history
z z
Recording of Max. 10000 operations. Writable to USB ash
drive.
Version display
z z
Version display, TPC MAC address, software version, writing
the TPC information
- (05 - 35) -