Design Technical Manual
Table Of Contents
- CHAPTER00
- CHAPTER01_General_information
- CHAPTER02_Model_selection
- 1. MODEL SELECTION PROCEDURE
- 2. MODEL LINE UP
- 3. MODEL SELECTION AND CAPACITY CALCULATION
- 4. CAPACITY TABLE COOLING (OUTDOOR UNIT)
- 5. CAPACITY TABLE HEATING (OUTDOOR UNIT)
- 6. CAPACITY COMPENSATION COEFFICIENT
- 7. CAPACITY TABLE COOLING (INDOOR UNIT)
- 7-1. COMPACT CASSETTE TYPE
- 7-2. CIRCULAR FLOW CASSETTE TYPE
- 7-3. CASSETTE TYPE
- 7-4. MINI DUCT TYPE
- 7-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 7-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 7-7. HIGH STATIC PRESSURE DUCT TYPE
- 7-8. VERTICAL AIR HANDLER TYPE
- 7-9. COMPACT FLOOR TYPE
- 7-10. FLOOR / CEILING TYPE
- 7-11. CEILING TYPE
- 7-12. WALL MOUNTED TYPE
- 8. CAPACITY TABLE HEATING (INDOOR UNIT)
- 8-1. COMPACT CASSETTE TYPE
- 8-2. CIRCULAR FLOW CASSETTE TYPE
- 8-3. CASSETTE TYPE
- 8-4. MINI DUCT TYPE
- 8-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 8-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 8-7. HIGH STATIC PRESSURE DUCT TYPE
- 8-8. VERTICAL AIR HANDLER TYPE
- 8-9. COMPACT FLOOR TYPE
- 8-10. FLOOR / CEILING TYPE
- 8-11. CEILING TYPE
- 8-12. WALL MOUNTED TYPE
- CHAPTER03_Outdoor_units
- CHAPTER04_Indoor_units
- CHAPTER05_Control_system
- 1. CONTROL SYSTEM
- 2. CONTROL UNITS
- 2-1. SYSTEM CONTROLLER
- 2-2. SYSTEM CONTROLLER LITE
- 2-3. TOUCH PANEL CONTROLLER
- 2-4. CENTRAL REMOTE CONTROLLER
- 2-5. WIRED REMOTE CONTROLLER (Touch panel)
- 2-6. WIRED REMOTE CONTROLLER
- 2-7. SIMPLE REMOTE CONTROLLER (With Operation mode)
- 2-8. SIMPLE REMOTE CONTROLLER (Without Operation mode)
- 2-9. WIRELESS REMOTE CONTROLLER
- 2-10. IR RECEIVER UNIT (for ALL DUCT TYPE)
- 2-11. IR RECEIVER UNIT (for CASSETTE TYPE)
- 2-12. IR RECEIVER UNIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-13. HUMAN SENSOR KIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-14. REMOTE SENSOR UNIT
- 2-15. PRESSURE SENSOR KIT
- 2-16. GROUP CONTROL METHOD
- 2-17. COMPARISON TABLE OF CONTROLLERS
- 3. ADAPTOR / CONVERTOR UNITS
- 4. SERVICE & WEB MONITORING TOOL
- CHAPTER06_System_design
- CHAPTER07_Function_setting
- CHAPTER08_External_input_and_output
- CHAPTER09_Notes
- CHAPTER10_Optional_parts
- CHAPTER99
3-6. MEDIUM STATIC PRESSURE DUCT TYPE
MODELS : ARUM24TLAV, ARUM30TLAV, ARUM36TLAV
ARUM24, ARUM30 ARUM36
Refrigerant pipe are
connection
Liquid ø 3/8 (9.52) ø 3/8 (9.52)
Gas ø 5/8 (15.88) ø 3/4 (19.05)
Drain hose - ø 3/4 (I.D.), ø 1-1/16 (O.D.)
Knock out hole (fresh air) - 7-7/8 (200)
Hole for power cable - 7/8 (23)
Unit : in. (mm)
Rear view
Front view
Top view
Side view (R)
Side view (L)
(Drain hose)
Drain port
Drain port
5-7/16 (138) 10-3/8 (264) 10-3/8 (264) 10-3/8 (264)
5-7/16 (138)
3-1/8 (80)
3-1/8 (80)
3-1/8 (80) 3-1/8 (80)
4-Ø1/8 (3.2) (hole)
P.C.D. Ø8-7/8 (225)
Ø8-1/16 (205) (hole)
3-1/4 (82)
2-15/16 (75)
10-5/8 (270)
1-1/4 (32)
Ø7-7/8 (200)
9-7/16 (240)
3-1/8 (80)3-1/8 (80)
6-5/16
(161)
4-Ø1/8 (3.2) (hole)
P.C.D. Ø8-7/8 (225)
3-1/8 (80)
3-1/8 (80)
4-3/4 (121)
Bolt pitch 46-5/16 (1177)
Bolt pitch
18-3/4 (477)
6-13/16 (173)
8-Ø3/16 (5) (hole)
P4-15/16 (125) x 3
= 14-3/4 (375)
P4-15/16 (125) x 3
= 14-3/4 (375)
4-3/4
(120)
2-7/8
(73)
2-3/16
(107)
39-15/16 (1015)
44-11/16 (1135)
1-9/16 (39)
2-1/8 (54)
4-1/2 (114)
2-5/8 (66)
1-1/4 (32)
7/8 (21.8)
27-9/16 (700)
7/8 (21.8)
1-9/16 (40)
6-5/8 (168)
9-7/16 (240)
11-1/16 (281)11-1/8 (283)
6-11/16
(170) 1-5/16 (34)
9-7/16 (240)
5/8 (16)
10-5/8 (270)
2-Ø3/16 (5) (hole)
(knock out hole)
Outlet
- (04-39) -
INDOOR
UNITS
INDOOR
UNITS