Design Technical Manual
Table Of Contents
- CHAPTER00
- CHAPTER01_General_information
- CHAPTER02_Model_selection
- 1. MODEL SELECTION PROCEDURE
- 2. MODEL LINE UP
- 3. MODEL SELECTION AND CAPACITY CALCULATION
- 4. CAPACITY TABLE COOLING (OUTDOOR UNIT)
- 5. CAPACITY TABLE HEATING (OUTDOOR UNIT)
- 6. CAPACITY COMPENSATION COEFFICIENT
- 7. CAPACITY TABLE COOLING (INDOOR UNIT)
- 7-1. COMPACT CASSETTE TYPE
- 7-2. CIRCULAR FLOW CASSETTE TYPE
- 7-3. CASSETTE TYPE
- 7-4. MINI DUCT TYPE
- 7-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 7-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 7-7. HIGH STATIC PRESSURE DUCT TYPE
- 7-8. VERTICAL AIR HANDLER TYPE
- 7-9. COMPACT FLOOR TYPE
- 7-10. FLOOR / CEILING TYPE
- 7-11. CEILING TYPE
- 7-12. WALL MOUNTED TYPE
- 8. CAPACITY TABLE HEATING (INDOOR UNIT)
- 8-1. COMPACT CASSETTE TYPE
- 8-2. CIRCULAR FLOW CASSETTE TYPE
- 8-3. CASSETTE TYPE
- 8-4. MINI DUCT TYPE
- 8-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 8-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 8-7. HIGH STATIC PRESSURE DUCT TYPE
- 8-8. VERTICAL AIR HANDLER TYPE
- 8-9. COMPACT FLOOR TYPE
- 8-10. FLOOR / CEILING TYPE
- 8-11. CEILING TYPE
- 8-12. WALL MOUNTED TYPE
- CHAPTER03_Outdoor_units
- CHAPTER04_Indoor_units
- CHAPTER05_Control_system
- 1. CONTROL SYSTEM
- 2. CONTROL UNITS
- 2-1. SYSTEM CONTROLLER
- 2-2. SYSTEM CONTROLLER LITE
- 2-3. TOUCH PANEL CONTROLLER
- 2-4. CENTRAL REMOTE CONTROLLER
- 2-5. WIRED REMOTE CONTROLLER (Touch panel)
- 2-6. WIRED REMOTE CONTROLLER
- 2-7. SIMPLE REMOTE CONTROLLER (With Operation mode)
- 2-8. SIMPLE REMOTE CONTROLLER (Without Operation mode)
- 2-9. WIRELESS REMOTE CONTROLLER
- 2-10. IR RECEIVER UNIT (for ALL DUCT TYPE)
- 2-11. IR RECEIVER UNIT (for CASSETTE TYPE)
- 2-12. IR RECEIVER UNIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-13. HUMAN SENSOR KIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-14. REMOTE SENSOR UNIT
- 2-15. PRESSURE SENSOR KIT
- 2-16. GROUP CONTROL METHOD
- 2-17. COMPARISON TABLE OF CONTROLLERS
- 3. ADAPTOR / CONVERTOR UNITS
- 4. SERVICE & WEB MONITORING TOOL
- CHAPTER06_System_design
- CHAPTER07_Function_setting
- CHAPTER08_External_input_and_output
- CHAPTER09_Notes
- CHAPTER10_Optional_parts
- CHAPTER99
MCA : Min Circuit Amps = Max Operating Current (Full Load).
MAX.CKT.BKR : Maximum Circuit Breaker.
FLA : Full Load Amps.
Indoor Unit Power Supply Indoor Rated
Type Model
Voltage
(V)
Frequency
(Hz)
MCA
(A)
MAX.CKT.
BKR
(A)
Input
Power
(kW)
Current
(A)
FLA
(A)
Compact oor
AGUA4TLAV1
230
60
0.22
15
0.014 0.13 0.17
AGUA7TLAV1
0.24 0.016 0.14 0.19
AGUA9TLAV1
0.25 0.017 0.15 0.20
AGUA12TLAV1
0.30 0.022 0.18 0.24
AGUA14TLAV1
0.38 0.029 0.23 0.30
Floor / ceiling
ABUA12TLAV
230 60
0.40
15
0.030 0.25
0.32
ABUA14TLAV 0.43 0.042 0.34
0.34
ABUA18TL AV 0.71 0.074 0.57
0.57
ABUA24TLAV 0.93 0.099 0.70
0.74
Ceiling
ABUA30TLAV
230 60
0.61
15
0.066 0.43
0.49
ABUA36TLAV 0.69 0.085 0.55
0.55
Wall mounted
ASUA4TLAV1
230 60
0.22
15
0.013 0.13 0.17
ASUA7TLAV1
0.32
0.019
0.19 0.25
ASUA9TLAV1
0.52 0.034 0.31 0.41
ASUA12TL AV1
0.42 0.025 0.25 0.33
ASUA14TL AV1
0.49 0.036 0.30 0.39
ASUB18TLAV1
0.53 0.032 0.33 0.42
ASUB24TLAV1
0.65 0.060 0.52 0.52
ASUB30TLAV1
0.90 0.074 0.55 0.72
ASUB36TLAV1
1.18 0.10 3 0.72 0.94
ASUA7TLAV 0.51 0.017 0.17
0.41
ASUA9TLAV 0.51 0.018 0.18
0.41
ASUA12TL AV 0.51 0.022 0.20
0.41
ASUA14TL AV 0.51 0.034 0.30
0.41
ASUB18TLAV 0.53 0.032 0.33
0.42
ASUB24TLAV 0.65 0.060 0.52
0.52
- (04-23) -
INDOOR
UNITS
INDOOR
UNITS