Design Technical Manual

Table Of Contents
Note : Specications are based on the following conditions.
Cooling : Indoor temperature of 80°F(26.7°C)DB/67°F(19.4°C)WB,and outdoor temperature of 95.0°F(35°C)DB/75°F(23.9°C)WB.
Heating : Indoor temperature of 70°F(21.1°C)DB/60°F(15.6°C)WB,and outdoor temperature of 47°F(8.3°C)DB/43°F(6.1°C)WB.
Pipe length : 25ft.(7.5 m), Height difference : 0ft.(0 m) (Outdoor unit - Indoor unit).
The protective function might work when using it outside the operation range.
1-11. CEILING TYPE
Model name ABUA30TLAV ABUA36TLAV
Power source 1 Phase ~ 208/230V 60Hz
Available voltage range 187 to 253 V
Capacity
Cooling
Btu/h 30,000 36,000
kW 8.8 10.6
Heating
Btu/h 34,000 40,000
kW 10.0 11.7
Input power W 66 85
Fan
Airow rate
High
CFM
(m
3
/ h)
959
(1,630)
995
(1,690)
Med
806
(1,370)
824
(1,400)
Low
671
(1,140)
689
(1,170)
Type x Quantity Sirocco × 4
Motor output W 106
Sound pressure
level
High
dB(A)
42 45
Med 38 38
Low 33 34
Heat exchanger
Length in. (mm) 53-1/8 (1,350)
Fin pitch FPI 16
Rows x Stages 3 × 12
3 ×12
8
Face Area ft
2
. (m
2
) 3.7 (0.34)
Pipe type (Material) Grooved H-pin (Copper)
Fin
Type (Material) Slit(Aluminum)
Surface
treatment
Hydrophilic coating
Air lter
Type Anti-mold
Net material PP monolament net
Enclosure
Material Plastic
Color
WHITE
Approximate color of MUNSELL N9.25
Dimensions
(H x W x D)
Net
in. (mm)
9-7/16 × 65-3/8 × 27 -9/16 (240 × 1,660 × 700)
Gross 12-1/2 × 70-7/8 × 31-1/8 (318 × 1,800 × 790)
Weight
Net
lbs. (kg)
101 (46) 106 (48)
Gross 130 (59) 134 (61)
Connection
pipe diameter
Liquid (Flare)
in. (mm)
ø 3/8 (9.52)
Gas (Flare) ø 5/8 (15.88) ø 3/4 (19.05)
Drain hose ø3/4 (19.05) [I.D.]; ø1-1/16 (26.6) [O.D.]
- (04-16) -
INDOOR
UNITS
INDOOR
UNITS