Design Technical Manual
Table Of Contents
- CHAPTER00
- CHAPTER01_General_information
- CHAPTER02_Model_selection
- 1. MODEL SELECTION PROCEDURE
- 2. MODEL LINE UP
- 3. MODEL SELECTION AND CAPACITY CALCULATION
- 4. CAPACITY TABLE COOLING (OUTDOOR UNIT)
- 5. CAPACITY TABLE HEATING (OUTDOOR UNIT)
- 6. CAPACITY COMPENSATION COEFFICIENT
- 7. CAPACITY TABLE COOLING (INDOOR UNIT)
- 7-1. COMPACT CASSETTE TYPE
- 7-2. CIRCULAR FLOW CASSETTE TYPE
- 7-3. CASSETTE TYPE
- 7-4. MINI DUCT TYPE
- 7-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 7-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 7-7. HIGH STATIC PRESSURE DUCT TYPE
- 7-8. VERTICAL AIR HANDLER TYPE
- 7-9. COMPACT FLOOR TYPE
- 7-10. FLOOR / CEILING TYPE
- 7-11. CEILING TYPE
- 7-12. WALL MOUNTED TYPE
- 8. CAPACITY TABLE HEATING (INDOOR UNIT)
- 8-1. COMPACT CASSETTE TYPE
- 8-2. CIRCULAR FLOW CASSETTE TYPE
- 8-3. CASSETTE TYPE
- 8-4. MINI DUCT TYPE
- 8-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 8-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 8-7. HIGH STATIC PRESSURE DUCT TYPE
- 8-8. VERTICAL AIR HANDLER TYPE
- 8-9. COMPACT FLOOR TYPE
- 8-10. FLOOR / CEILING TYPE
- 8-11. CEILING TYPE
- 8-12. WALL MOUNTED TYPE
- CHAPTER03_Outdoor_units
- CHAPTER04_Indoor_units
- CHAPTER05_Control_system
- 1. CONTROL SYSTEM
- 2. CONTROL UNITS
- 2-1. SYSTEM CONTROLLER
- 2-2. SYSTEM CONTROLLER LITE
- 2-3. TOUCH PANEL CONTROLLER
- 2-4. CENTRAL REMOTE CONTROLLER
- 2-5. WIRED REMOTE CONTROLLER (Touch panel)
- 2-6. WIRED REMOTE CONTROLLER
- 2-7. SIMPLE REMOTE CONTROLLER (With Operation mode)
- 2-8. SIMPLE REMOTE CONTROLLER (Without Operation mode)
- 2-9. WIRELESS REMOTE CONTROLLER
- 2-10. IR RECEIVER UNIT (for ALL DUCT TYPE)
- 2-11. IR RECEIVER UNIT (for CASSETTE TYPE)
- 2-12. IR RECEIVER UNIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-13. HUMAN SENSOR KIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-14. REMOTE SENSOR UNIT
- 2-15. PRESSURE SENSOR KIT
- 2-16. GROUP CONTROL METHOD
- 2-17. COMPARISON TABLE OF CONTROLLERS
- 3. ADAPTOR / CONVERTOR UNITS
- 4. SERVICE & WEB MONITORING TOOL
- CHAPTER06_System_design
- CHAPTER07_Function_setting
- CHAPTER08_External_input_and_output
- CHAPTER09_Notes
- CHAPTER10_Optional_parts
- CHAPTER99
1-5-4. CONTROLLER EXTERNAL INPUT / OUTPUT FUNCTION
SUMMARY
CONTROLLER EXTERNAL INPUT FUNCTION
Central
controller
(Input function)
Dry
contact /
Apply
voltage
Function Specications
Emergency
stop
Batch on /
Batch off
Terminal
Signal
type
External power supply
Wire
size /
length
Allowable
voltage
Allowable
current
Touch
Panel
Controller
Dry
contact
●
(Screen icon)
●
(Screen icon)
TM201 (CH1-K1,K2)
[CN201 ↔ CN411]
Edge
- -
AWG22
Twist /
82 ft.
(25 m)
TM201 (CH1-K1,K2)
(CH2- K1,K 2)
[CN201 ↔ CN411]
Pulse *1
Apply
voltage
●
(Screen icon)
●
(Screen icon)
TM201 (CH1-K1,K2)
[CN201 ↔ CN412]
Edge
DC 12 [V]
10 mA or
less
TM201 (CH1-K1,K2)
(CH2- K1,K 2)
[CN201 ↔ CN412]
Pulse *1
Central
Remote
Controller
Dry
contact
●
(Screen icon)
●
(Screen icon)
CN6 (PIN1-2) Edge
- -
CN6 (Ch1:PIN1-2)
CN7 (Ch2:PIN1-2)
Pulse *1
Apply
voltage
●
(Screen icon)
●
(Screen icon)
CN11 (PIN1-3) Edge
DC 24 [V]
5 mA or
less
CN11 (Ch1:PIN1-3)
CN12 (Ch2:PIN1-3)
Pulse *1
*1 : Default setting is Edge signal, if you use pulse signal, must be set pulse signal from screen icon.
CONTROLLER EXTERNAL OUTPUT FUNCTION
Central Controller
(Output Function)
Dry
contact /
Apply
voltage
Function Specications
Operation
status
Error
status
Terminal
External power supply
Wire
size/ length
Allowable
voltage
Allowable
current
Touch
Panel
Controller
Apply
voltage
●
-
CN410
(PIN1-2)
DC 12 [V]
15 mA
or less
AWG22
Twist /
Max.
82 ft.
(25 m)
-
●
CN410
(PIN3-4)
Central
Remote
Controller
Apply
voltage
●
-
CN9
(PIN3-4)
-
●
CN9
(PIN1-2)
- (08 - 68) -
EXTERNAL INPUT
& OUTPUT
EXTERNAL INPUT
& OUTPUT