Design and Technical Manual

2. MODEL SELECTION
MODEL : ASU18RLF
Outdoor Temperature
Indoor temperature (°CDB)
15.6 18.3 21.1 23.9 25.6
CDB) (°CWB) TC TC TC TC TC
-15.0 -16.1 4.59 4.25 3.92 3.61 3.19
-10.0 -11.1 5.13 4.76 4.39 4.04 3.58
-5.0 -7. 2 5.71 5.29 4.88 4.49 3.98
0.0 -2.2 6.24 5.78 5.33 4.90 4.34
5.0 2.8 6.69 6.20 5.72 5.26 4.66
8.3 6.1 6.84 6.35 5.85 5.38 4.77
10.0 8.3 6.84 6.35 5.85 5.38 4.77
15.0 10.0 6.84 6.35 5.85 5.38 4.77
20.0 15.0 6.84 6.35 5.85 5.38 4.77
23.9 18.3 6.84 6.35 5.85 5.38 4.77
MODEL : ASU24RLF
Outdoor Temperature
Indoor temperature (°CDB)
15.6 18.3 21.1 23.9 25.6
CDB) (°CWB) TC TC TC TC TC
-15.0 -16.1 6.21 5.76 5.31 4.88 4.32
-10.0 -11.1 6.95 6.44 5.94 5.46 4.84
-5.0 -7. 2 7.73 7.17 6.61 6.08 5.38
0.0 -2.2 8.44 7. 8 3 7.22 6.64 5.88
5.0 2.8 9.05 8.40 7.74 7.12 6.31
8.3 6.1 9.27 8.59 7.92 7.29 6.45
10.0 8.3 9.27 8.59 7.92 7.29 6.45
15.0 10.0 9.27 8.59 7.92 7.29 6.45
20.0 15.0 9.27 8.59 7.92 7.29 6.45
23.9 18.3 9.27 8.59 7.92 7.29 6.45
HEATING CAPACITY
in kW
TC : Total Capacity kW.
The data is based on the following conditions.
Pipe length : 16.4ft.(5m) [Outdoor unit - Branch box], 9.8ft. (3m) [Branch box - Indoor unit]
Height difference : 0 ft.(0m) [Outdoor unit - Indoor unit].
- (02 - 47) -
MODEL
SELECTION
MODEL
SELECTION