Design and Technical Manual

2. MODEL SELECTION
MODEL : ASU9RLS2
Outdoor Temperature
Indoor temperature (°CDB)
15.6 18.3 21.1 23.9 25.6
CDB) (°CWB) TC TC TC TC TC
-15.0 -16.1 2.34 2.17 2.00 1.84 1.64
-10.0 -11.1 2.62 2.43 2.24 2.06 1.84
-5.0 -7. 2 2.92 2.71 2.49 2.29 2.04
0.0 -2.2 3.19 2.96 2.72 2.51 2.23
5.0 2.8 3.42 3.17 2.92 2.69 2.40
8.3 6.1 3.50 3.24 2.99 2.75 2.45
10.0 8.3 3.50 3.24 2.99 2.75 2.45
15.0 10.0 3.50 3.24 2.99 2.75 2.45
20.0 15.0 3.50 3.24 2.99 2.75 2.45
23.9 18.3 3.50 3.24 2.99 2.75 2.45
MODEL : ASU12RLS2
Outdoor Temperature
Indoor temperature (°CDB)
15.6 18.3 21.1 23.9 25.6
CDB) (°CWB) TC TC TC TC TC
-15.0 -16.1 3.10 2.88 2.65 2.44 2.18
-10.0 -11.1 3.47 3.22 2.97 2.73 2.44
-5.0 -7. 2 3.86 3.58 3.30 3.04 2.71
0.0 -2.2 4.22 3.91 3.61 3.32 2.96
5.0 2.8 4.53 4.20 3.87 3.56 3.17
8.3 6.1 4.63 4.30 3.96 3.64 3.25
10.0 8.3 4.63 4.30 3.96 3.64 3.25
15.0 10.0 4.63 4.30 3.96 3.64 3.25
20.0 15.0 4.63 4.30 3.96 3.64 3.25
23.9 18.3 4.63 4.30 3.96 3.64 3.25
MODEL : ASU15RLS2
Outdoor Temperature
Indoor temperature (°CDB)
15.6 18.3 21.1 23.9 25.6
CDB) (°CWB) TC TC TC TC TC
-15.0 -16.1 3.76 3.49 3.22 2.96 2.64
-10.0 -11.1 4.21 3.91 3.60 3.31 2.95
-5.0 -7. 2 4.68 4.34 4.00 3.68 3.28
0.0 -2.2 5.12 4.74 4.37 4.02 3.59
5.0 2.8 5.49 5.09 4.69 4.31 3.85
8.3 6.1 5.62 5.21 4.80 4.42 3.94
10.0 8.3 5.62 5.21 4.80 4.42 3.94
15.0 10.0 5.62 5.21 4.80 4.42 3.94
20.0 15.0 5.62 5.21 4.80 4.42 3.94
23.9 18.3 5.62 5.21 4.80 4.42 3.94
HEATING CAPACITY
in kW
TC : Total Capacity kW.
The data is based on the following conditions.
Pipe length : 16.4ft.(5m) [Outdoor unit - Branch box], 9.8ft. (3m) [Branch box - Indoor unit]
Height difference : 0 ft.(0m) [Outdoor unit - Indoor unit].
- (02 - 45) -
MODEL
SELECTION
MODEL
SELECTION