Design and Technical Manual

2. MODEL SELECTION
MODEL : ASU7RLF
Outdoor Temperature
Indoor temperature (°FDB)
60.0 65.0 70.0 75.0 78.0
FDB) FWB) TC TC TC TC TC
5.0 3.0 6.34 5.88 5.42 4.98 4.44
14.0 12.0 7.10 6.58 6.06 5.58 4.97
23.0 19.0 7.8 9 7. 32 6.74 6.20 5.53
32.0 28.0 8.62 7.9 9 7. 37 6.78 6.04
41.0 37.0 9.24 8.57 7.90 7.27 6.48
47.0 43.0 9.46 8.77 8.10 7.44 6.63
50.0 47. 0 9.46 8.77 8.10 7. 4 4 6.63
59.0 50.0 9.46 8.77 8.10 7. 4 4 6.63
68.0 59.0 9.46 8.77 8.10 7.44 6.63
75.0 65.0 9.46 8.77 8.10 7.44 6.63
MODEL : ASU9RLF
Outdoor Temperature
Indoor temperature (°FDB)
60.0 65.0 70.0 75.0 78.0
FDB) FWB) TC TC TC TC TC
5.0 3.0 8.02 7. 4 4 6.86 6.31 5.62
14.0 12.0 8.98 8.33 7.68 7. 0 6 6.30
23.0 19.0 9.99 9.26 8.54 7. 8 5 7.00
32.0 28.0 10.91 10.12 9.32 8.58 7. 6 5
41.0 37.0 11.70 10.85 10.00 9.20 8.20
47.0 43.0 11.98 11.11 10.20 9.42 8.39
50.0 47. 0 11.98 11.11 10.20 9.42 8.39
59.0 50.0 11.98 11.11 10.20 9.42 8.39
68.0 59.0 11.98 11.11 10.20 9.42 8.39
75.0 65.0 11.98 11.11 10.20 9.42 8.39
MODEL : ASU12RLF
Outdoor Temperature
Indoor temperature (°FDB)
60.0 65.0 70.0 75.0 78.0
FDB) FWB) TC TC TC TC TC
5.0 3.0 10.59 9.82 9.05 8.33 7. 42
14.0 12.0 11.86 10.99 10.13 9.32 8.31
23.0 19.0 13.18 12.23 11.27 10.37 9.24
32.0 28.0 14.40 13.36 12.31 11.32 10.09
41.0 37.0 15.44 14.32 13.20 12.14 10.82
47.0 43.0 15.81 14.66 13.50 12.43 11.08
50.0 47. 0 15.81 14.66 13.50 12.43 11.08
59.0 50.0 15.81 14.66 13.50 12.43 11.08
68.0 59.0 15.81 14.66 13.50 12.43 11.08
75.0 65.0 15.81 14.66 13.50 12.43 11.08
HEATING CAPACITY
in kBtu/h
TC : Total Capacity kBtu/h.
The data is based on the following conditions.
Pipe length : 16.4ft.(5m) [Outdoor unit - Branch box], 9.8ft. (3m) [Branch box - Indoor unit]
Height difference : 0 ft.(0m) [Outdoor unit - Indoor unit].
- (02 - 42) -
MODEL
SELECTION
MODEL
SELECTION