Design and Technical Manual

4. INDOOR UNITS
SAFETY DEVICES10.
Model and type PCB fuse
Fan motor
thermal
protector
Terminal
thermal fuse
Float
switch
Compact Cassette
AUU7RLF
250V 3.15A
OFF: 268
+ 30
- 34
°F
(131
+ 17
- 19
°C)
ON: 210
+ 38
- 34
°F
(99
+ 21
- 19
°C)
AUU9RLF
AUU12RLF
AUU18RLF
Slim Duct
ARU7RLF
250V 3.15A
OFF: 275 ± 27°F
(135 ± 15°C)
ON: 239 ± 27°F
(115 ± 15°C)
ARU9RLF
ARU12RLF
ARU18RLF
ARU24RLF
Wall Mounted
ASU7RLF1
250V 3.15A
OFF: 221 ± 18°F
(105 ± 10°C)
ON: 194 ± 18°F
(90 ± 10°C)
ASU9RLF1
ASU12RLF1
ASU7RLF
250V 3.15A
OFF: 230 ± 27°F
(110 ± 15°C)
ON: 203 ± 27°F
(95 ± 15°C)
OFF: 216°F
(OFF: 102°C)
ASU9RLF
ASU12RLF
ASU9RLS2
OFF: 320 ± 45°F
(160 ± 25°C)
ON: 230 ± 45°F
(110 ± 25°C)
ASU12RLS2
ASU15RLS2
ASU18RLF
250V 3.15A
OFF: 302 ± 27°F
(150 ± 15°C)
ON: 248 ± 27°F
(120 ± 15°C)
OFF: 216°F
(OFF: 102°C)
ASU24RLF
Floor
AGU9RLF
250V 3.15A
OFF: 302 ± 27°F
(150 ± 15°C)
ON: 248 ± 27°F
(120 ± 15°C)
OFF: 216°F
(OFF: 102°C)
AGU12RLF
AGU15RLF
- (04 - 95) -
INDOOR
UNITS
INDOOR