Spec Sheet
Flexible Installation
Dimensions
Specifications
(a) Direct connection to flange
*
2
: Length of connecting duct must be within 39-3/8 inches.
*
1:
Attachment is not necessary.
(b) Connection with rectangular duct
Flange of Slim Duct*1
Rectangular duct*2(Field supplied)
Slim Duct
Cable
Slim duct
cable
UTD-GXSA-W
W1
W2
26-7/8
34-3/4
25-13/32
33-1/4
7-3/32
5-13/16
11/32
3-5/16
Unit: in.
Model Name
H1
H2
D1 D2
UTD-GXSB-W
Auto Louver Grille
W1
W2
D2D1
H1
H2
Auto Louver Grille can be connected either directly to indoor unit or through the rectangular duct.
Copyright© 2013 Fujitsu General Limited. All rights reserved.
Product specifications are subject to change without notice.
Bracket Frame
Grille
Auto Louver Grille
Bracket Frame
Fitting Frame
Grille
Grille
}
}
Model name
UTD-GXSA-W* UTD-GXSB-W*
Applicable Indoor Unit
Power Supply Connecting with Control box of indoor unit
Fixing of Auto Louver Grille Screw fixing to Flange or Rectangular Duct
Extension Square Duct Limit 39-3/8” (Max. duct length between indoor unit and grille)
Net Dimension
(H x W x D)
inch
(mm)
7-3/32x26-7/8x(3-5/16+11/32)
[180x683x(84+9)]
7-3/32x34-3/4x(3-5/16+11/32)
[180x883x(84+9)]
Weight
Net
lb.
(kg)
6.7 (3.0) 7.8 (3.5)
Gross
4.4 (2.0) 5.6 (2.5)
Color White
Louver Motor Stepping Motor
Accessories Fitting Frame, etc.
Operation
range
Cooling
°F (°C) 64 to 90 (18 to 32)
% RH 80% or less
Heating °F (°C) 50 to 86 (10 to 30)
ARU9RLF, ARU12RLF ARU18RLF
353 Route 46 West, Fairfield, NJ 07004
www.fujitsugeneral.com
FUJITSU GENERAL AMERICA, INC.
* Only compatible with ARU models with serial numbers greater than 2000.
UTD-GXSC-W
UTD-GXSC-W*
ARU24RLF
Coming Soon
42-5/8
41-1/8
7-3/32x42-5/8x(3-5/16+11/32)
[180x1083x(84+9)]
6.7 (3.0)
8.9 (4.0)