Manual

68 SPARC Enterprise T5140 and T5240 Servers Administration Guide February 2008
7. Configure the new hard drive.
Type the following command:
For example:
The green Activity LED flashes as the new disk at c1t3d0 is added to the device
tree.
8. Verify that the new hard drive is in the device tree.
Type the following command:
Note that c0t3d0 is now listed as configured.
# cfgadm -c configure Ap-Id
# cfgadm -c configure c1::dsk/c0t3d0
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 disk connected configured unknown
c0::dsk/c0t1d0 disk connected configured unknown
c0::dsk/c0t2d0 disk connected configured unknown
c0::dsk/c0t3d0 disk connected configured unknown
c1 scsi-bus connected configured unknown
c1::dsk/c1t0d0 CD-ROM connected configured unknown
usb0/1 unknown empty unconfigured ok
usb0/2 unknown empty unconfigured ok
usb1/1.1 unknown empty unconfigured ok
usb1/1.2 unknown empty unconfigured ok
usb1/1.3 unknown empty unconfigured ok
usb1/1.4 unknown empty unconfigured ok
usb1/2 unknown empty unconfigured ok
#