Manual

64 SPARC Enterprise T5140 and T5240 Servers Administration Guide February 2008
To Perform a Mirrored Disk Hot-Plug Operation
1. Verify which hard drive corresponds with which logical device name and
physical device name.
See “Disk Slot Numbers, Logical Device Names, and Physical Device Names” on
page 53.
2. To confirm a failed disk, type the following command:
If the Disk Status is FAILED, then the drive can be removed and a new drive
inserted. Upon insertion, the new disk should be OK and the volume should be
RESYNCING.
For example:
This example indicates that the disk mirror has degraded due to a failure in disk
c0t2d0.
Note The logical device names might appear differently on your system,
depending on the number and type of add-on disk controllers installed.
3. Remove the hard drive, as described in your servers service manual.
There is no need to issue a software command to bring the drive offline when the
drive has failed.
4. Install a new hard drive, as described in your servers service manual.
The RAID utility automatically restores the data to the disk.
# raidctl
# raidctl
RAID Volume RAID RAID Disk
Volume Type Status Disk Status
--------------------------------------------------------
c0t1d0 IM DEGRADED c0t1d0 OK
c0t2d0 FAILED