Note The maximum operating input current values are based on P / (V * 0.95),
where P=maximum operating input power, V=input voltage. Example: 662 / (110 *
0.95) = 6.33 A at 110 VAC. You can use this equation to calculate the maximum
operating input current for your specific input voltage.
Related Information
“Acoustic Noise Emissions” on page 8
Acoustic Noise Emissions
Declared noise emissions for both the SPARC Enterprise T5120 and T5220 servers are
in accordance with ISO 9296 standards.
Related Information
“Agency Compliance Specifications” on page 9
TABLE 9 Acoustic Noise Emissions for the SPARC Enterprise T5120 Server
Description Mode Specification
LwAd (1 B = 10 dB) Operating acoustic noise
Idling acoustic noise
7.0 B
7.0 B
LpAm (bystander positions) Operating acoustic noise
Idling acoustic noise
59 dB
59 dB
TABLE 10 Acoustic Noise Emissions for the SPARC Enterprise T5220 Server
Description Mode Specification
LwAd (1 B = 10 dB) Operating acoustic noise
Idling acoustic noise
7.4 B
7.4 B
LpAm (bystander positions) Operating acoustic noise
Idling acoustic noise
63 dB
63 dB