Servers User's Guide
Table Of Contents
- SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers RCI User’s Guide
- Preface
- Contents
- Figures
- CHAPTER 1 RCI Overview
- CHAPTER 2 Setup of the RCI for Operation
- 2.1 Overview of RCI Setup
- 2.2 RCI Setup for Initial Installation
- 2.2.1 RCI setup flow
- 2.2.2 Confirming RCI initialization
- . To confirm RCI initialization:
- 2.2.3 Connecting RCI cables
- 2.2.4 Making an RCI address setting
- . To specify an RCI address:
- . To confirm an RCI address:
- 2.2.5 Making an RCI construction setting
- . To make an RCI construction setting:
- . To confirm an RCI construction setting:
- 2.3 RCI Setup for Addition of an RCI I/O Unit
- 2.4 RCI Setup for Addition of an RCI Base Cabinet
- 2.4.1 RCI setup flow
- 2.4.2 Confirming RCI initialization
- . To confirm RCI initialization:
- 2.4.3 Connecting an RCI cable
- 2.4.4 Making an RCI address setting
- . To specify an RCI address:
- . To confirm the specified RCI address:
- 2.4.5 Making an RCI expansion setting
- . To make an RCI expansion setting:
- . To confirm an RCI expansion setting:
- 2.5 RCI Setup for Replacement of an RCI I/O Unit
- 2.6 RCI Setup for Replacement of an RCI Base Cabinet
- 2.6.1 RCI setup flow
- 2.6.2 Replacing an RCI host
- 2.6.3 Confirming RCI initialization
- . To confirm RCI initialization:
- 2.6.4 Connecting an RCI cable
- 2.6.5 Making an RCI address setting
- . To specify an RCI address:
- . To confirm the specified RCI address:
- 2.6.6 Making an RCI replacement setting
- . To make an RCI replacement setting:
- . To confirm an RCI replacement setting:
- CHAPTER 3 Command Reference
- CHAPTER 4 Error Status

3-4 C120-E360-06EN
CHAPTER 3 Command Reference
I/F RCI unit interface status.
ACT Valid state.
INACT Invalid state.
sys-phase Operating state of the host connected to RCI.
One of the following is displayed:
power-off Powered off.
panic In the panic state.
shdwn-start Shutdown in progress.
shdwn-cmplt Shutdown has completed.
dump-cmplt Dump has completed.
booting System being started.
running System in operation.
- Not support the status display.
ctgry Category of the RCI unit.
One of the following is displayed:
host Host unit.
disk File unit.
rcic External power control device.
linesw Line switch.
Other Other devices.
dev-cls Device class of the RCI unit.
sub-cls Subdevice class of the RCI unit.
tm-out Idle monitoring timeout period of RCI. Since it doesn't support the status
display, "-" is always displayed.
• "-c init" needs to be executed in the system power-off status.
• "When -c initconfig", "-c addconfig", or "-c replaceconfig" is being executed, or the
setrcic(8) command is being executed, do not execute the setrci(8) command on another
host.
• When the setrci(8) command is executed, set all RCI units that are connected to RCI into
the power-on state or standby state.
• Executing the setrci(8) command on a model that does not support the RCI function
causes an error to occur.