Technical data
TX300 S5 Operating manual 89
Troubleshooting and tips Added drive reported as defective
7.8 Added drive reported as defective
RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê Remove and reinstall the drive while the system is switched ON.
If the hard disk drive continues to be shown as defective, then replace it (see
"Hot-plug hard disk drives" on page 93).
I Further information is provided in the "Integrated RAID for SAS User’s
Guide" (on the PRIMERGY ServerView Suite DVD 2 under Industry
Standard Servers - Expansion Cards - Storage Adapters - LSI RAID / SCSI
Controllers) or in the "Modular RAID Controller Installation Guide" (on the
PRIMERGY ServerView Suite DVD 2 under Industry Standard Servers -
Expansion Cards - Storage Adapters - LSI RAID / SCSI Controllers).
For more information on configuring the controller, see section "Config-
uring the server" on page 79.
7.9 Error message on screen
The meaning of the error message is explained in the documentation for the
relevant components and programs on the PRIMERGY ServerView Suite
DVD 2.