Technical data

48 Operating manual TX300 S5
Installing/removing the rack model Hardware installation
Mounting the support system
Figure 4: Mounting the left support system
Ê Place the left support system in the support bracket with the two retaining
bolts in the two outer square catches (1).
Ê Clamp the left support system between the front left support upright and the
support bracket by pressing it together, positioning it on the front support
upright and releasing it again (2).
The support system automatically adjusts to the rack depth.
Ê Fasten the left support system with a centering fixture M5 to the left front
support upright (3).
Ê Repeat the above steps with the right-hand support system (it is secured to
the front and rear right support uprights).
Ê Fit the cage nuts for securing the server in the corresponding catches on the
right and left support uprights.
Ê Fit the PRIMECENTER/DataCenter rack cable management as described in
the technical manual for the corresponding rack.
Ê Insert the server (see section "Inserting the server" on page 49).