Technical data

TX300 S5 Operating manual 105
CSS components Non-hot-plug components
8.2 Non-hot-plug components
V CAUTION!
The actions described in this section may only be performed by
personnel with the appropriate technical training. (The device can be
seriously damaged if it is opened without authorization or if repairs are
attempted by untrained personnel.)
Please observe the safety information in chapter "Important information"
on page 25.
If a defective non-hot-plug component is detected (further information can be
found in chapter "Starting up and operation" on page 65 and the "PRIMERGY
ServerView Suite Local Service Concept - LSC" manual on the PRIMERGY
ServerView Suite DVD 2), proceed as follows:
Ê Exit all applications and shut down the server properly (see section
"Switching the server on and off" on page 77).
Ê Unplug all power plugs.
Ê Open the server (see section "Opening/closing the housing" on page 111).
Ê Press the Indicate CSS button on the system board (see the technical
manual for the system board D2619).
The PRIMERGY Diagnostic LED of the defective CSS component lights up
orange, thereby indicating which CSS component (memory module, fan or
expansion card) on the system board must be replaced (see technical
manual for the system board D2619).