Datasheet

System configurator and order-information guide
T
PRIMERGY BX400 System Unit Status: 2013-03-28
Section
VI
Connection Blades Fibre Channel
S26361-K1305-V14 S26361-K1305-V26 S26361-K1305-V126
S26361-K1305-V314 *) S26361-K1305-V326 *) S26361-K1305-V327 *)
PY CB FC Switch 8Gb 18/8 14 PY CB FC Switch 8Gb 18/8 26 PY CB FC SW 8G 18/8 26 Perform
Brocade 5450 Brocade 5450 Brocade 5450
with 14 port licence with 26 port licence
with Performance Bundle
18x downlink + 8 uplink
18x downlink + 8 uplink
18x downlink + 8 uplink
Full Fabric license Full Fabric license
Adv. Zoning, Adv. Web Tools Adv. Zoning, Adv. Web Tools
Performance Bundle
4 x 8Gb/s SFP+ included 4 x 8Gb/s SFP+ included
4 x 8Gb/s SFP+ included
external: 8x connectors for external: 8x connectors for external: 8x connectors for
8Gb SFP+ or 4Gb SFP modules
8Gb SFP+ or 4Gb SFP modules
8Gb SFP+ or 4Gb SFP modules
max. 3x per System Unit
max. 3x per System Unit max. 3x per System Unit
max. 3x
S26361-F2749-E1
*)
Service for Blade installation
for separate delivery, without blade chassis
in the System Unit.
Hereby the BX900 S1 will
be delivered completely
configured and tested
with the Blade integrated.
1x per Switch Blade
S26361-F3873-E104 S26361-F3873-E109
S26361-F3873-E204
S26361-F3873-E208
max. 4x FC 4Gb/s SFP Multi Mode (MMF) FC 8Gb/s SFP+ Multi Mode (MMF) FC 4Gb/s SFP Multi Mode (SMF) FC 8Gb/s SFP+ Multi Mode (SMF)
requires LC connector cable requires LC connector cable requires LC connector cable requires LC connector cable
max. 4x per switch max. 4x per switch
max. 4x per switch
max. 4x per switch
The Brocade 5450 with the 14 port license can by upgraded by the
12 port upgarde license S26361-F3873-L12.
only the above listes SFPs will be supported by the switches
other SFPs will not be switched on by the switch FOS
S26361-K1363-V18
S26361-K1363-V318
*)
PY CB FC Pass Thru 8G 18/18 *)
PRIMERGY FC Pass Thru for separate delivery, without blade chassis
18x downlink + 18 uplink
no SFP Modules included
external: 18x connectors for
Note: not released for CB2 in Fabric 2!
8Gb SFP+ or 4Gb SFP modules
max. 2x per System Unit
max. 2x
S26361-F2749-E1
Service for Blade installation
in the System Unit.
Hereby the BX900 S1 will
be delivered completely
configured and tested
with the Blade integrated.
1x per Pass Thru Blade
S26361-F3873-E104
S26361-F3873-E109
max. 18x
FC 4Gb/s SFP Multi Mode (MMF) FC 8Gb/s SFP+ Multi Mode (MMF)
requires LC connector cable requires LC connector cable
max. 18x per Pass Thru Blade max. 18x per Pass Thru Blade
FC Connection Blades can only be used in fabric 2 (CB 2) and 3 (CB 3/4) of the System Unit.
U