Leaflet
Data Sheet ⏐ Issue: April 18, 2004 ⏐ PRIMERGY LTO2HH Ultrium tape drive Page 2 / 2
All rights, including rights created by patent grant or registration of a utility model or design as well
as rights of technical modifications are reserved. Delivery subject to availability. Designations may
be trademarks, the use of which by third parties for their own purposes may violate the rights of the
trademark owners.
Copyright © Fujitsu Siemens Computers, 04/2005
Published by
Fujitsu Siemens Computers
http://www.fujitsu-siemens.com/
Company stamp
Technical Data
Capacity
uncompressed
compressed
200 GB
400 GB
Buffer size 64 MB
Transfer rate
maximal
variable
(depending on System
performance or Media type)
uncompressed/compressed
24 / 48 MB/s
18 / 36 MB/s, 12 / 24 MB/s
Record format Ultrium LTO2
System interface Ultra160 SCSI Protocol
(U320 Chipset)
Data transfer rate
(burst)
160 MB/s
Number of tracks 512
Data cassettes LTO Ultrium 1 + 2
File access time 76s
Backward compatible Read-/write compatible with
LTO Ultrium 1 + 2
Data compression ALDC
Tape Alert yes
Reliability
MTBF (hours) 250,000
Hard Read Error Rate 1 x 10
-17
Reed Solomon ECC yes
Mean Time to repair <30 minutes
Tape motion
Tape speed
Read/write
LTO 2
166ips
LTO 1
172ips
Wind / Rewind 200ips
Dimension / weight
Internal drive
Height/Wide/depth
Weight
42 x 146 x 210 mm
1,4 kg
Electricity consumption
activity input
Standby
in operation
5V 2,1 A
12V 0,6 A
Electricity consumption
6 W standby
18 W typical at Read/Write
Temperature
Operation 10
o
C up to 35
o
C
bearing -40
o
C up to 60
o
C
Relative humidity
operation
20% up to 80% C
Relative humidity bearing 5% up to 90% C
Compliance with Norm and standards
Product safety
Global IEC 60950
Europe EN 60950
USA / Canada UL 60950 C-UL, C22.2 No. 60950
Electro magnetic
compatibility
Europe EN 55022 Class B;
EN 55024
Taiwan -
Japan -
Australian / New
Zealand
AS/NZS 3548 Class B
USA / Canada FCC Part 15 Class B /
ICES-003 Class B
Declaration of conformity
Europe (CE) CE (LVD + EMC)
North America FCC
Approvals
Product safety
Global -
Europe TÜV
Germany TÜV
USA / Canada ULc/us
There is general compliance with the safety requirements of all
European countries and North America. National approvals
required in order to satisfy statutory regulations or for other
reasons (e.g. for Canada and USA, East European countries,
Norway), can be applied for on request.