System information

RX2520 M1
Upgrade and Maintenance Manual 329
System board and components
UFM: install the UFM spacer to the system board and install the UFM see
section "Installing the UFM" on page 295
TPM (if applicable): see section "Installing the TPM" on page 304
Ê "Installing the power backplane" on page 110
Ê "Installing the fan box" on page 146
Ê "Reassembling" on page 57
Ê If applicable, activate TPM functionality in the system BIOS under Security >
TPM (Security Chip) Setting > Security Chip. For more information, refer to the
corresponding BIOS Setup Utility Reference Manual.
Ê Reconnect all external cables.
Ê "Connecting the server to the power source" on page 62
Ê "Updating or recovering the system board BIOS and iRMC" on page 73
Ê "Verifying system information backup / restore" on page 75
Ê "Verifying the system time settings" on page 84
Ê Inform the customer about changed WWN and MAC addresses. For further
information, refer to section "Looking up changed MAC / WWN addresses"
on page 89.
Ê After replacing the system board in a server running Linux OS, "Updating the
NIC configuration file in a Linux environment" on page 86
Ê "Enabling SVOM boot watchdog functionality" on page 82
Ê "Enabling BitLocker functionality" on page 88
Ê Reconfigure your network settings in the operation system according to the
original configuration of the replaced controller (expansion card or onboard).
I Configuration of network settings should be performed by the
customer.
For further information, please refer to section "Note on network
settings recovery" on page 321.
Ê If applicable, "After replacing the system board" on page 92.