System information
RX2520 M1
Upgrade and Maintenance Manual 255
Accessible drives
Ê Fasten the tape drive dummy module with 2 screws.
Ê Insert the drive cage into bay 2, for further information see sectjon "Installing
the RDX drive" on page 248.
Ê Insert the HDD cage into bay 1, for further information see sectjon "Installing
a HDD cage" on page 139.
Ê If applicable, remove the USB 3.0 interface card as describe in section
"Removing an expansion card" on page 165
12.9.4 Concluding steps
Ê "Installing the fan box" on page 146
Ê "Reassembling" on page 57
Ê "Connecting the server to the power source" on page 62
Ê "Switching on the server" on page 64
Ê "Verifying and configuring the backup software solution" on page 79
Ê "Enabling BitLocker functionality" on page 88
12.10 Replacing the RDX drive in 2.5-inch version
12.10.1 Preliminary steps
Ê "Disabling BitLocker functionality" on page 65
Ê "Locating the defective server" on page 47
Ê "Removing backup and optical disk media" on page 69
Ê "Verifying and configuring the backup software solution" on page 69
Ê "Shutting down the server" on page 49
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver