System information

104 Upgrade and Maintenance Manual
RX2520 M1
Power supply units
6.4.3 Installing the new hot-plug power supply unit
Figure 20: Installing the hot-plug power supply unit
Ê Insert the power supply unit into its slot.
Ê Push the power supply unit into its slot (1) as far as it will go until the locking
latch snaps in place (2).
V CAUTION!
Ensure that the power supply unit properly engages in its slot and is
locked in position in order to prevent it from sliding out of the chassis
during transportation.
Ê If applicable, fold down the handle on the power supply unit(3).
6.4.4 Concluding steps
Ê "Connecting the server to the power source" on page 62
Ê In non-redundant PSU configurations, swich on the server as described in
section "Switching on the server" on page 64
Ê "Performing a fan test after replacing a defective fan" on page 93