Operation Manual
Table Of Contents
- Contents
- 1 Preface
- 2 Installation steps, overview
- 3 Important information
- 4 Hardware installation
- 5 Starting up and operation
- 5.1 Access to the drives (floorstand model)
- 5.2 Control elements and indicators
- 5.3 Switching the server on and off
- 5.4 Configuring the server
- 5.4.1 Configuring the onboard SATA controller
- 5.4.2 Configuring the SAS/SATA RAID controller
- 5.4.3 Configuring the server and installing the operating system with the ServerView Installation Manager
- 5.4.4 Configuring the server and installing the operating system without the ServerView Installation Manager
- 5.5 Cleaning the server
- 6 Property and data protection
- 7 Troubleshooting and tips
- 7.1 Power-on indicator remains unlit
- 7.2 Server switches itself off
- 7.3 Screen remains blank
- 7.4 Flickering stripes on monitor screen
- 7.5 No screen display or display drifts
- 7.6 No mouse pointer displayed on screen
- 7.7 Incorrect date and time
- 7.8 Drives reported as “dead” when starting system
- 7.9 Added drive reported as defective
- 7.10 Error message on screen
- 7.11 Expansion cards or onboard devices not recognized
- 7.12 Temperature warning
- 7.13 No effect of keyboard or mouse
- 7.14 Optical drive cannot read data
- 8 CSS components
- 8.1 Hot-plug components
- 8.2 Non-hot-plug components
- 9 Appendix: server specification
- Index

TX150 S7 Operating Manual 91
CSS components Hot-plug components
8.1.1.2 Adding a second hot-plug power supply unit
A second hot-plug power supply unit can be added to ensure a redundant power
supply. If one power supply unit fails, the second power supply unit ensures that
operation continues unimpaired.
The slot for the second hot-plug power supply unit contains a dummy module,
which must be removed before installing the second power supply unit.
Figure 20: Removing the dummy module
Ê Push the green catch in the direction of the arrow (1) , push the dummy
module upwards (2) and unhook it at the bottom.
V CAUTION!
Store the dummy module in a safe place. If the power supply unit is
removed and not replaced with a new unit, then the dummy module
must be reinstalled due to cooling, the applicable EMC regulations
(regulations on electromagnetic compatibility) and fire protection.
Ê Insert the second power supply unit into the free slot (see section "Replacing
the hot-plug power supply unit" on page 90) and connect it to the mains (see
section "Connecting the server to the mains" on page 56).
/