Operation Manual
Table Of Contents
- Contents
- 1 Preface
- 2 Installation steps, overview
- 3 Important information
- 4 Hardware installation
- 5 Starting up and operation
- 5.1 Access to the drives (floorstand model)
- 5.2 Control elements and indicators
- 5.3 Switching the server on and off
- 5.4 Configuring the server
- 5.4.1 Configuring the onboard SATA controller
- 5.4.2 Configuring the SAS/SATA RAID controller
- 5.4.3 Configuring the server and installing the operating system with the ServerView Installation Manager
- 5.4.4 Configuring the server and installing the operating system without the ServerView Installation Manager
- 5.5 Cleaning the server
- 6 Property and data protection
- 7 Troubleshooting and tips
- 7.1 Power-on indicator remains unlit
- 7.2 Server switches itself off
- 7.3 Screen remains blank
- 7.4 Flickering stripes on monitor screen
- 7.5 No screen display or display drifts
- 7.6 No mouse pointer displayed on screen
- 7.7 Incorrect date and time
- 7.8 Drives reported as “dead” when starting system
- 7.9 Added drive reported as defective
- 7.10 Error message on screen
- 7.11 Expansion cards or onboard devices not recognized
- 7.12 Temperature warning
- 7.13 No effect of keyboard or mouse
- 7.14 Optical drive cannot read data
- 8 CSS components
- 8.1 Hot-plug components
- 8.2 Non-hot-plug components
- 9 Appendix: server specification
- Index

54 Operating Manual TX150 S7
Installing/removing the rack model Hardware installation
Racks with installation depth of 735 mm
The lengths of the telescopic rails do not need to be adjusted with respect to
each other for the installation in rack systems with 735 mm installation depth.
Ê Secure the support systems as described in section "Installing the support
systems" on page 50.
Ê Mount the server (see "Inserting the server" on page 51) and route the
cables as described in the original manual of the rack..
V CAUTION!
Ensure that the safety lock has been inserted before the server is
inserted (see figure 5 on page 50).
Racks with installation depth smaller/greater than 735 mm
The support systems can be used for installation depths of 714 - 785 mm. The
spring element of the support system is used to adjust the length as required.
Ê Secure the support systems as described in "Installing the support systems"
on page 50.
Ê Mount the server (see "Inserting the server" on page 51) and route the
cables as described in the original manual of the rack..
V CAUTION!
Ensure that the safety lock has been inserted before the server is
inserted (see figure 5 on page 50).