Installing/removing the rack model Hardware installation
Racks with installation depth of 735 mm
The lengths of the telescopic rails do not need to be adjusted with respect to
each other for the installation in rack systems with 735 mm installation depth.
Ê Secure the support systems as described in section "Installing the support
systems" on page 50.
Ê Mount the server (see "Inserting the server" on page 51) and route the
cables as described in the original manual of the rack..
V CAUTION!
Ensure that the safety lock has been inserted before the server is
inserted (see figure 5 on page 50).
Racks with installation depth smaller/greater than 735 mm
The support systems can be used for installation depths of 714 - 785 mm. The
spring element of the support system is used to adjust the length as required.
Ê Secure the support systems as described in "Installing the support systems"
on page 50.
Ê Mount the server (see "Inserting the server" on page 51) and route the
cables as described in the original manual of the rack..
V CAUTION!
Ensure that the safety lock has been inserted before the server is
inserted (see figure 5 on page 50).