Operation Manual
Table Of Contents
- Contents
- 1 Preface
- 2 Installation steps, overview
- 3 Important information
- 4 Hardware installation
- 5 Starting up and operation
- 5.1 Access to the drives (floorstand model)
- 5.2 Control elements and indicators
- 5.3 Switching the server on and off
- 5.4 Configuring the server
- 5.4.1 Configuring the onboard SATA controller
- 5.4.2 Configuring the SAS/SATA RAID controller
- 5.4.3 Configuring the server and installing the operating system with the ServerView Installation Manager
- 5.4.4 Configuring the server and installing the operating system without the ServerView Installation Manager
- 5.5 Cleaning the server
- 6 Property and data protection
- 7 Troubleshooting and tips
- 7.1 Power-on indicator remains unlit
- 7.2 Server switches itself off
- 7.3 Screen remains blank
- 7.4 Flickering stripes on monitor screen
- 7.5 No screen display or display drifts
- 7.6 No mouse pointer displayed on screen
- 7.7 Incorrect date and time
- 7.8 Drives reported as “dead” when starting system
- 7.9 Added drive reported as defective
- 7.10 Error message on screen
- 7.11 Expansion cards or onboard devices not recognized
- 7.12 Temperature warning
- 7.13 No effect of keyboard or mouse
- 7.14 Optical drive cannot read data
- 8 CSS components
- 8.1 Hot-plug components
- 8.2 Non-hot-plug components
- 9 Appendix: server specification
- Index

46 Operating Manual TX150 S7
Installing/removing the rack model Hardware installation
I For PRIMECENTER Racks and DataCenter Racks:
The mounting of the rails in the different racks is described in the next
sections. Installation of the cable management is described in detail in
the Technical Manual for the respective rack.
I For 19-inch standard rack (for the Japanese market):
For information on mounting of the rails in the19-inch standard rack (for
the Japanese market) please refer to the Rack mount guide.
3rd party racks
Certain general conditions must be met:
– Installation dimensions (see the dimensions shown in figure 3 on page 47):
1 Front of rack
2 Rear of rack
A Rack depth (comparison PRIMECENTER Rack 940/1000/1100 mm)
B Rack width (comparison PRIMECENTER rack 700 mm)
C Clearance for 19” installation level
C1 Front 19” installation level
C2 Rear 19” installation level
D Cable routing area (cable area depth) and ventilation
E Space for front panel and ventilation
F Space for right and left support systems
P PRIMERGY rack installation depth
a1 Front left support upright
a2 Front right support upright
b1 Rear left support upright
b2 Rear right support upright