Operation Manual
Table Of Contents
- Contents
- 1 Preface
- 2 Installation steps, overview
- 3 Important information
- 4 Hardware installation
- 5 Starting up and operation
- 5.1 Access to the drives (floorstand model)
- 5.2 Control elements and indicators
- 5.3 Switching the server on and off
- 5.4 Configuring the server
- 5.4.1 Configuring the onboard SATA controller
- 5.4.2 Configuring the SAS/SATA RAID controller
- 5.4.3 Configuring the server and installing the operating system with the ServerView Installation Manager
- 5.4.4 Configuring the server and installing the operating system without the ServerView Installation Manager
- 5.5 Cleaning the server
- 6 Property and data protection
- 7 Troubleshooting and tips
- 7.1 Power-on indicator remains unlit
- 7.2 Server switches itself off
- 7.3 Screen remains blank
- 7.4 Flickering stripes on monitor screen
- 7.5 No screen display or display drifts
- 7.6 No mouse pointer displayed on screen
- 7.7 Incorrect date and time
- 7.8 Drives reported as “dead” when starting system
- 7.9 Added drive reported as defective
- 7.10 Error message on screen
- 7.11 Expansion cards or onboard devices not recognized
- 7.12 Temperature warning
- 7.13 No effect of keyboard or mouse
- 7.14 Optical drive cannot read data
- 8 CSS components
- 8.1 Hot-plug components
- 8.2 Non-hot-plug components
- 9 Appendix: server specification
- Index

TX150 S7 Operating Manual 45
Hardware installation Installing/removing the rack model
4.3 Installing/removing the rack model
V CAUTION!
● Please observe the safety information and notes on rack mounting in
chapter "Important information" on page 27.
● At least two people are needed to install / remove the server in the
rack. (For the Japanese market, please refer to " 安全上の注意および
その他の重要情報 ".)
● The rack may tip over if more than one unit is removed at the same
time.
● The server may not occupy the top height units of the rack
(38HU/42HU PRIMECENTER Rack, DataCenter Rack,
19-inch standard rack (for the Japanese market)),
as otherwise boards cannot be replaced even with the plug-in module
fully extended.
4.3.1 Rack system requirements
The rack systems from Fujitsu PRIMECENTER Rack, DataCenter Rack and
19-inch standard rack (for the Japanese market) support the installation of
PRIMERGY servers. Installation in most current rack systems from other
manufacturers (3rd party racks) is also supported.
To accommodate the ventilation concept and ensure proper ventilation, any
unused areas in the rack must be sealed using dummy covers.
The power is supplied via the multiple socket outlets fitted in the rack.
Fujitsu rack systems
The main features of PRIMECENTER Rack, DataCenter Rack and 19-inch
standard rack (for the Japanese market) are as follows:
– support systems that can be mounted without tools
– support systems having a linear alignment feature to ensure that they can
be adjusted to different rack depths
PRIMECENTER Rack and DataCenter Rack provide an enhanced cable
management in the lateral rack area.