Operation Manual
Table Of Contents
- Contents
- 1 Preface
- 2 Installation steps, overview
- 3 Important information
- 4 Hardware installation
- 5 Starting up and operation
- 5.1 Access to the drives (floorstand model)
- 5.2 Control elements and indicators
- 5.3 Switching the server on and off
- 5.4 Configuring the server
- 5.4.1 Configuring the onboard SATA controller
- 5.4.2 Configuring the SAS/SATA RAID controller
- 5.4.3 Configuring the server and installing the operating system with the ServerView Installation Manager
- 5.4.4 Configuring the server and installing the operating system without the ServerView Installation Manager
- 5.5 Cleaning the server
- 6 Property and data protection
- 7 Troubleshooting and tips
- 7.1 Power-on indicator remains unlit
- 7.2 Server switches itself off
- 7.3 Screen remains blank
- 7.4 Flickering stripes on monitor screen
- 7.5 No screen display or display drifts
- 7.6 No mouse pointer displayed on screen
- 7.7 Incorrect date and time
- 7.8 Drives reported as “dead” when starting system
- 7.9 Added drive reported as defective
- 7.10 Error message on screen
- 7.11 Expansion cards or onboard devices not recognized
- 7.12 Temperature warning
- 7.13 No effect of keyboard or mouse
- 7.14 Optical drive cannot read data
- 8 CSS components
- 8.1 Hot-plug components
- 8.2 Non-hot-plug components
- 9 Appendix: server specification
- Index

28 Operating Manual TX150 S7
Safety instructions Important information
Before starting up
V CAUTION!
● During installation and before operating the device, observe the
instructions on environmental conditions for your device (see section
"Technical data" on page 23).
● If the server has been moved from a cold environment, condensation
may form both inside and on the outside of the machine.
Wait until the server has acclimatized to room temperature and is
absolutely dry before starting it up. Material damage may be caused
to the server if this requirement is not met.
● Only transport the server in the original packaging or in packaging
that protects it from impacts and jolts.
Installation and operation
V CAUTION!
● This unit should not be operated in ambient temperatures above
35 °C.
● If the unit is integrated into an installation that draws power from an
industrial power supply network with an IEC309 connector, the power
supply's fuse protection must comply with the requirements for non-
industrial power supply networks for type A connectors.
● The unit automatically adjusts itself to a mains voltage in a range of
100 V - 240 V. Ensure that the local mains voltage lies within these
limits.
● This device must only be connected to properly grounded power
outlets or insulated sockets of the rack's internal power supply with
tested and approved power cables.
● Ensure that the device is connected to a properly grounded power
outlet close to the device.