Operation Manual
Table Of Contents
- Contents
- 1 Preface
- 2 Installation steps, overview
- 3 Important information
- 4 Hardware installation
- 5 Starting up and operation
- 5.1 Access to the drives (floorstand model)
- 5.2 Control elements and indicators
- 5.3 Switching the server on and off
- 5.4 Configuring the server
- 5.4.1 Configuring the onboard SATA controller
- 5.4.2 Configuring the SAS/SATA RAID controller
- 5.4.3 Configuring the server and installing the operating system with the ServerView Installation Manager
- 5.4.4 Configuring the server and installing the operating system without the ServerView Installation Manager
- 5.5 Cleaning the server
- 6 Property and data protection
- 7 Troubleshooting and tips
- 7.1 Power-on indicator remains unlit
- 7.2 Server switches itself off
- 7.3 Screen remains blank
- 7.4 Flickering stripes on monitor screen
- 7.5 No screen display or display drifts
- 7.6 No mouse pointer displayed on screen
- 7.7 Incorrect date and time
- 7.8 Drives reported as “dead” when starting system
- 7.9 Added drive reported as defective
- 7.10 Error message on screen
- 7.11 Expansion cards or onboard devices not recognized
- 7.12 Temperature warning
- 7.13 No effect of keyboard or mouse
- 7.14 Optical drive cannot read data
- 8 CSS components
- 8.1 Hot-plug components
- 8.2 Non-hot-plug components
- 9 Appendix: server specification
- Index

TX150 S7 Operating Manual 19
Preface Features
iRMC S2 with integrated service LAN connector
I The features of the iRMC S2 Advanced Video Redirection and Remote
Storage are available as an option.
The iRMC S2 (integrated Remote Management Controller) is a BMC with
integrated service LAN connector and expanded functionality that was
previously only available with additional plug-in cards. In this way, the iRMC S2
enables complete control of PRIMERGY servers, regardless of system status,
and thus particularly the control of PRIMERGY servers that are in the "out-of-
band" system status.
Major functions supported by the iRMC S2 include the following:
● Browser access via iRMC S2-s own Web server
● Secure communication (SSH, SSL)
● Power Management for the managed server (depending on its system
status)
● Power Consumption Management
● Connecting virtual drives as remote storage
● Text-based and graphic console bypass (Advanced Video Redirection)
● Command Line Interface (CLI)
● Simple, interactive or script-based iRMC S2 configuration
● Customer Self Service (CSS)
● iRMC S2-s own user management
● Multi-computer, global iRMC S2 user administration using an LDAP
Directory Service
● Automatic network configuration via DNS / DHCP
● Power supply of the iRMC S2 via the system standby supply
● Full-coverage alarm management
● System Event Log (SEL) reading and processing
More information about the iRMC S2 can be found in the "iRMC S2 - integrated
Remote Management Controller" user’s guide (on the PRIMERGY
ServerView Suite DVD 2 under Industry Standard Servers - Software - PRIMERGY
ServerView Suite - Out-Of-Band Management).