Operation Manual
Table Of Contents
- Contents
- 1 Preface
- 2 Installation steps, overview
- 3 Important information
- 4 Hardware installation
- 5 Starting up and operation
- 5.1 Access to the drives (floorstand model)
- 5.2 Control elements and indicators
- 5.3 Switching the server on and off
- 5.4 Configuring the server
- 5.4.1 Configuring the onboard SATA controller
- 5.4.2 Configuring the SAS/SATA RAID controller
- 5.4.3 Configuring the server and installing the operating system with the ServerView Installation Manager
- 5.4.4 Configuring the server and installing the operating system without the ServerView Installation Manager
- 5.5 Cleaning the server
- 6 Property and data protection
- 7 Troubleshooting and tips
- 7.1 Power-on indicator remains unlit
- 7.2 Server switches itself off
- 7.3 Screen remains blank
- 7.4 Flickering stripes on monitor screen
- 7.5 No screen display or display drifts
- 7.6 No mouse pointer displayed on screen
- 7.7 Incorrect date and time
- 7.8 Drives reported as “dead” when starting system
- 7.9 Added drive reported as defective
- 7.10 Error message on screen
- 7.11 Expansion cards or onboard devices not recognized
- 7.12 Temperature warning
- 7.13 No effect of keyboard or mouse
- 7.14 Optical drive cannot read data
- 8 CSS components
- 8.1 Hot-plug components
- 8.2 Non-hot-plug components
- 9 Appendix: server specification
- Index

TX150 S7 Operating Manual 17
Preface Features
SAS/SATA RAID controller
The server is available with the following SAS/SATA RAID controllers for
operating the internal SAS/SATA hard disk drives:
– Modular RAID 0/1 controller with "Integrated Mirroring Enhanced"
(SAS IME) for SAS1.0
RAID levels 0, 1 and 1E are supported for internal hard disk drive
configurations.
I For the Japanese market only RAID level 1 is supported for internal
hard disk drive configurations.
– Modular RAID 0/1 controller with “MegaRAID functionality”
(SAS MegaRAID) for SAS2.0
RAID levels 0, 1,10 and 1E are supported for internal hard disk drive
configurations.
– Modular RAID 5/6 controller with "MegaRAID functionality"
(SAS MegaRAID) for SAS1.0 and SAS2.0
RAID levels 0, 1, 10, 1E, 5, 50, 6 and 60 are supported for internal hard disk
drive configurations. As an option, a battery backup unit (BBU) can save the
memory content even if the power fails. Cache memory sizes of 256 Mbyte
and 512 Mbyte are available.
I For more information on configuring the controller, see section
"Configuring the SAS/SATA RAID controller" on page 75.
Further information on SAS/SATA RAID controllers is provided in the
"Modular RAID Controller Installation Guide" (on PRIMERGY
ServerView Suite DVD 2 under Industry Standard Servers - Expansion Cards
- Storage Adapters - LSI RAID / SCSI Controllers).
Further information on other SAS/SATA RAID controllers (e.g. for
operating external SAS/SATA hard disk drives or tape drives) is available
on PRIMERGY ServerView Suite DVD 2 under Industry Standard Servers