Operation Manual
Table Of Contents
- Contents
- 1 Preface
- 2 Installation steps, overview
- 3 Important information
- 4 Hardware installation
- 5 Starting up and operation
- 5.1 Access to the drives (floorstand model)
- 5.2 Control elements and indicators
- 5.3 Switching the server on and off
- 5.4 Configuring the server
- 5.4.1 Configuring the onboard SATA controller
- 5.4.2 Configuring the SAS/SATA RAID controller
- 5.4.3 Configuring the server and installing the operating system with the ServerView Installation Manager
- 5.4.4 Configuring the server and installing the operating system without the ServerView Installation Manager
- 5.5 Cleaning the server
- 6 Property and data protection
- 7 Troubleshooting and tips
- 7.1 Power-on indicator remains unlit
- 7.2 Server switches itself off
- 7.3 Screen remains blank
- 7.4 Flickering stripes on monitor screen
- 7.5 No screen display or display drifts
- 7.6 No mouse pointer displayed on screen
- 7.7 Incorrect date and time
- 7.8 Drives reported as “dead” when starting system
- 7.9 Added drive reported as defective
- 7.10 Error message on screen
- 7.11 Expansion cards or onboard devices not recognized
- 7.12 Temperature warning
- 7.13 No effect of keyboard or mouse
- 7.14 Optical drive cannot read data
- 8 CSS components
- 8.1 Hot-plug components
- 8.2 Non-hot-plug components
- 9 Appendix: server specification
- Index

118 Operating Manual TX150 S7
Index
environmental protection 39
error
drifting display on monitor 83
drive “dead” 84
drive defective 84
incorrect date 84
incorrect time 84
no display on monitor 83
no mouse pointer 83
power-on indicator does not
light 81
screen remains blank 82
screen shows flickering
stripes 83
server switches itself off 82
Error Correcting Code 18
error message on screen 85
ESD (electrostatic-sensitive
devices) 34
expansion card
installing 110
removing 109
F
fault
drifting display on monitor 83
drive defective 84
incorrect date 84
incorrect time 84
no display on monitor 83
screen remains blank 82
screen shows flickering
stripes 83
FCC statement 36
features 14
flash EPROM 21
G
Global Error indicator 62, 64, 67
H
hard disk activity indicator 62, 64
hard disk drive 16
handling 96
installation frame 92
hard disk drive indicators 66
HDD module 18, 92
acclimatization time 41, 96
installation frame 99
installing 99
hot-plug HDD module 18
hot-plug power supply unit 56, 89
dummy module
91
replacing 90
I
ID button 62, 64
ID card 62, 63
product name 42, 63
serial number 42, 63
ID indicator 62, 65, 68
IME 17, 75
indicators
CSS 62, 65, 68
DVD drive activity 62, 65
Global Error 62, 64, 67
hard disk activity 62, 64
hard disk drive 66
ID 62, 65, 68
on power supply unit 70
on server 62
operation 62
system error 64, 67
information, additional 13
installation, server 45
installing in
3rd party rack 53
DataCenter rack 48
PRIMECENTER rack 48
installing in the rack, notes 38
installing the operating system 77
Integrated Mirroring Enhanced 17,
75
integrated Remote Management
Controller 19
iRMC S2 19