Before Reading This Manual Thank you for purchasing the PRIMERGY 4Gbit/s FC I/O Module (hereinafter referred to as this product). This manual explains the 4Gbit/s FC I/O Modules and the Fibre Channel driver (for Windows). Read this manual carefully to handle the product correctly. For details about the Fibre Channel driver, refer to manuals supplied with the server blade or the Fujitsu PRIMERGY website: (http://primergy.fujitsu.
Remarks Warning Descriptions Various symbols are used throughout this manual. These are provided to emphasize important points for your safety and that of others. The symbols and their meanings are as follows. Be sure to fully understand these before reading this manual. WARNING Ignoring this symbol could be potentially lethal. CAUTION Ignoring this symbol may lead to injury and/or damage the device or hardware options.
Abbreviations The following expressions and abbreviations are used to describe the product names used in this manual.
Checking the Items Supplied Check that the following items are supplied before using this product. Please contact an office listed in "Appendix B Contact Information" ( pg.75) if any parts are missing. • 4Gbit/s FC I/O Module (this product) • Driver Disk × 1 (CD-ROM) - 4Gbit/s FC I/O Module (PG-FCD201) Drivers CD • User's Guide (this document) • Screw (3 screws) Microsoft, Windows, Windows Server are registered trademarks or trademarks of the Microsoft Corporation in the USA and other countries.
Contents 1 4Gbit/s FC I/O Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 1.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 1.2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 1.3 How to Check the Driver Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 1.4 4Gbit/s FC I/O Module to ETERNUS Connections . . . . . . . . . . . . . . 48 1.
44
1 4Gbit/s FC I/O Module This chapter explains the features and specifications of this product. 1.1 Overview This product is a Fibre Channel expansion board for use exclusively with BX620 S3 and BX620 S4 server blades. This product is configured with one dual port (2 ports) Fibre Channel controller, it is supplied to connect to external storage Fibre Channels. Use only the FC Switch Blade connected to network blade slots 3 or network blade slots 4 (NET 3 or NET4) to access the external storage.
1.2 Specifications This product is an expansion board used in order to install fiber channel interface on the server blade. This product has the following features: • Capable of high-speed data transfer at a maximum rate of 4Gbps. • You can place the connected device away from the server. • Uses thin and light cables so they can be easily connected.
1.3 How to Check the Driver Version The following explains the procedure to check the driver version. 1 Click the "Start" button → "Settings" → "Control Panel" → "Administrative Tools" → "Computer Management" in this order. 2 Click "Device Manager". 3 Double-click "SCSI and RAID controllers". 4 Double-click the driver to be checked (Emulex Lightpulse ********* Storport Miniport Driver). 5 Click the [Driver] tab. • For 32Bit 5-1.30.9 • For 64Bit 7-1.30.9 6 Click the [Driver Details].
1.4 4Gbit/s FC I/O Module to ETERNUS Connections This section explains the connection of the 4Gbit/s FC I/O Module and ETERNUS. Fabric connection Connect to the ETERNUS via FC Switch Blade. BX600 S3 chassis PRIMERGY BX620 S3/BX620 S4 FC Switch Blade (PG-FCS103) PG-FCD201 ETERNUS3000/ ETERNUS6000 FC Switch Blade (PG-FCS103) 1.
2 Installing the 4Gbit/s FC I/O Module This chapter explains the installation procedure in the server blade. WARNING • When installing or removing this product, make sure to remove the server blade from the chassis. Failure to do so may cause electric shock. For details on how to remove the server blade from the chassis, refer to "Blade Server System Unit Hardware Guide". CAUTION • The circuit boards and soldered parts of internal options are exposed. They can be damaged by static electricity.
2.1.1 Installation Position of the 4Gbit/s FC I/O Module The 4Gbit/s FC I/O Module is installed in the server blade expansion board slot. Expansion board slot 2.1.2 Installation Procedure for the 4Gbit/s FC I/O Module 1 Turn off the server blade where the 4Gbit/s FC I/O Module will be installed. → "3.3 Turning Off the Server" in "Blade Server System Unit Hardware Guide" 2 Touch a metal part of the chassis to discharge static electricity from your body. 3 Remove the server blade from the chassis.
5 Install the 4Gbit/s FC I/O Module. Make sure the 4Gbit/s FC I/O Module is securely on the slot. [Rear] 4Gbit/s FC I/O Module Expansion board slot 6 Secure the 4Gbit/s FC I/O Module with the screws. Secure the 4Gbit/s FC I/O Module with three screws included with this product. Screws 7 Attach the top cover. →"7.2 Removing and Attaching the Top Cover" in "Server Blade User's Guide" 8 Install the server blade in the chassis. →"4.
3 Connecting Cables This chapter explains points to note when connecting cables. Connect the cable to the FC Network Blade installed in the BX600 S3 chassis, or the port used by the FC Network Blade. Each cable connector has a protrusion which determines the inserting direction of the connector. When connecting the cable, check this protrusion to make sure of the inserting direction of the connector, and then push the connector as far as it will go.
4 Installing Drivers and Utilities This chapter explains the procedure for installing drivers and utilities. When installing drivers, logon using administrator privileges. • For installing drivers and utility (HBAnyware) at the same time. "4.1 Automatic Installation"(pg.53) • For installing drivers and utility (HBAnyware) manually. "4.2 Manual Installation"(pg.55) 4.
1. 2. 3. 4. 5. Click [Next]. Select "Find the best driver for the device", and click [Next]. Check only "CD-ROM drive", and then click [Next]. Click [Next]. Click [Finish]. 7 Click [Finish]. When "System Settings Change" appears, click [Yes] to restart the system. 8 Refer to "1.3 How to Check the Driver Version" ( pg.47) to check the driver version. When automatic installation finishes, perform "4.3 Checking and Updating Firmware /BootBIOS" ( pg.58).
4.2 Manual Installation Drivers and utilities can be manually installed using the following procedures. 4.2.1 For Installation on Windows Server 2003 When "Welcome to the Found New Hardware Wizard" appears during startup, click [Cancel]. Installing Emulex PLUS 1 Click the "Start" button → "Control Panel" → "Add Hardware" in this order. 2 Click [Next]. 3 Check "Yes, I have already connected the hardware", and click [Next].
Installing *****port Miniport Driver 1 Click the "Start" button → "Administrative Tools" → "Computer Management" in this order. 2 Click [Device Manager]. 3 Select "Emulex **********" in the "SCSI and RAID controllers" or "Other devices" list and double-click it. If the displayed name is "Emulex LightPulse ***** Storport Miniport Driver" and the driver version is "5.1.30.9" or "7.1.30.9" , the driver will be installed, please close the properties screen.
12 Check the driver version. • For 32Bit 5.1.30.9 • For 64Bit 7.1.30.9 13 Close the board property window. When installation finishes, perform "4.2.2 Installing HBAnyware" ( pg.57). 4.2.2 Installing HBAnyware 1 Insert the driver disk (CD-ROM) into the CD-ROM drive, and execute "setupapps.exe" in the driver disk. [CD-ROM drive]: \v1.30a9\AutoPilot Installer\Utilities\setupapps.exe 2 Click [Next]. 3 Select "Full Management", check "Allow users to change management mode from utility.", and click [OK].
4.3 Checking and Updating Firmware / BootBIOS There are two methods to check and update Firmware/BootBIOS. The results will bring no difference. "4.3.1 Using LightPulse Utility / NT"(pg.58) "4.3.2 Using HBAnyware Utility"(pg.60) 4.3.1 Using LightPulse Utility / NT This product name displayed in LightPulse Utility/NT is "Adapter * - BX600-FC42E * Port *". 1 Click the "Start" button → "Programs" or "All Programs" → "Emulex" → "lpUtilNT" in this order.
7 For the BootBIOS version, check the "Revision" value in "Boot Bios Firmware". • When the version is "1.70a3", proceed to Step 11. • When the version is other than "1.70a3", proceed to Step 8. 8 Click the [Download] button. Although the warning window appears, click [OK]. 9 Insert the driver disk (CD-ROM) into the CD-ROM drive, select the BootBIOS file in the CD-ROM drive, and click [Open]. [CD-ROM drive]:\FirmBIOS\ZB170A3.PRG BootBIOS update starts.
4.3.2 Using HBAnyware Utility This product name displayed in HBAnyware Utility is "BX600-FC42E - 10:00:**:**:**:**:**:**". The "**:**:**:**:**:**" shows the IEEE address of the 4Gbit/s FC I/O Module. Each 4Gbit/s FC I/ O Module has a unique IEEE address, which is written on the sticker on each 4Gbit/s FC I/O Module. 1 Click the "Start" button → "Programs" or "All Programs" → "Emulex" → "HBAnyware" in this order. 2 Select the target 4Gbit/s FC I/O Module, and click the "Firmware" tab.
8 For the BootBIOS version, check the "BootBIOS" value in "Boot BIOS". • When the version is "1.70a3", proceed to Step 13. • When the version is other than "1.70a3", proceed to Step 9. 9 Click the "Update Firmware..." in "Firmware". When the confirmation dialog appears, click [Yes]. 10 Insert the driver disk (CD-ROM) into the CD-ROM drive, select the BootBIOS file in the CD-ROM drive, and click [Start Download]. [CD-ROM drive]:\FirmBIOS\ZB170A3.PRG 11 When the Firmware update is completed, click [Close].
5 4Gbit/s FC I/O Module Details Setting This chapter explains the 4Gbit/s FC I/O Module details settings. When performing this product details settings, log on with administrative privileges. When the connected device to this product is ETERNUS SX300, refer to the User’s Guide, etc. for ETERNUS SX300.
5.1 4Gbit/s FC I/O Module Setting There are two methods for this product setting. The results will bring no difference. "5.1.1 Using LightPulse Utility / NT"(pg.63) "5.1.2 Using HBAnyware Utility"(pg.68) 5.1.1 Using LightPulse Utility / NT This product name displayed in LightPulse Utility/NT is "Adapter * -BX600FC42E -* Port *".
4 Select the adapter for which settings are changed from the adapter list on the left of the window, and double-click "Topology" in "Parameters". When there are two or more adapters, refer to "Appendix A How to Identify the Adapter" ( pg.74). 5 Set a value for "New Value" depending on the connection type, check "Permanent", and click [Change]. When the connection type varies for each adapter, remove the check from the "Global" checkbox.
7 Set a value in "New Value", check "Permanent", and click [Change]. When the settings vary for each adapter, remove the check on the "Global".
8 Double-click "QueueTarget" in "Parameters". 9 Set "1" (fixed value) in "New Value", check "Permanent", and click [Change]. 10 Double-click "LinkSpeed" in "Parameter". 11 Set a value in "New Value", check "Permanent", and click [Change]. For the setting values, refer to the ETERNUS Server Connection Guide, etc. • When setting to "1Gb", set "1" to "New Value". • When setting to "2Gb", set "2" to "New Value". • When setting to "4Gb", set "4" to "New Value".
• When Topology is 0, QueueDepth is 8, and QueueTarget is 1 for all the adapters: 13 When the settings for all adapters finishes, select "Exit" from "File" menu, and exit LightPulse Utility/NT. After exiting LightPulse Utility/NT perform "5.2 Registry Setting" ( pg.71).
5.1.2 Using HBAnyware Utility This product name displayed in HBAnyware Utility/NT is "BX600FC42E - 10:00:**:**:**:**:**:**". The "**:**:**:**:**:**" shows the IEEE address of the 4Gbit/s FC I/O Module. Each 4Gbit/s FC I/ O Module has a unique IEEE address, which is written on the sticker on each 4Gbit/s FC I/O Module. For PG-FCD201, there are two adapters and two IEEE Addresses. Due to this there are two IEEE address labels.
• When selected the adapter to be set and "Driver Parameters" (Individual setting for each adapter) In the above diagram, "BX620 S3" represents a local server, and "BX600-FC42E 10:00:00:00:C9:48:FE:0C" represents an installed 4Gbit/s FC I/O Module. 3 Click [Topology] in "Adapter Parameter". 4 Select a value representing the connection type from the list box to "Value" in "Modify Adapter Parameter", and click [Apply].
For ETERNUS4000 model 300/500 and ETERNUS8000 Specify "255". 7 Double-click "QueueTarget" in "Adapter Parameters". 8 Set "1" (fixed value) in "Value" in "Modify Adapter Parameter", and click [Apply]. 9 Click "LinkSpeed" in "Adapter Parameters". 10 Select the value from the list box to "Value" in "Modify Adapter Parameter", and click [Apply]. For the setting values, refer to the ETERNUS Server Connection Guide, etc.
5.2 Registry Setting 1 Click the "Start" button → "Run..." in this order. 2 Enter a name in "Name" as follows, and click [OK]. regedit The registry editor starts. 3 Follow the paths below. \HKEY_LOCAL_MACHINE \SYSTEM \CurrentControlSet \Services \Disk 4 Check that the key name "TimeOutValue" values have the relations described in the table below.
6 Troubleshooting This chapter explains the troubleshooting methods when this product is not running properly or when error messages are displayed. 6.1 Checking the Link Status The link status connection can be checked upon system start by starting the Light Pulse BIOS Utility. How to start the Light Pulse BIOS Utility When this product is installed, the following message appears at the system startup. !!! BX600-FC42E BIOS, Copyright (c) 2005 Emulex !!! Version 1.
6.2 Troubleshooting Check the applicable items listed below if this product does not operate correctly. If the problem is not resolved even after taking the following measures, contact an office listed in "Appendix B Contact Information" ( pg.75). Symptoms Items to be checked Remedies This product is not recognized by the server.
Appendix A How to Identify the Adapter This chapter explains how to identify the adapter. Each 4Gbit/s FC I/O Module has an IEEE Address. The IEEE Address is on a sticker on the front or rear of this product. For PG-FCD201, there are two adapters and two IEEE Addresses. Due to this there are two IEEE address labels. The IEEE Address value mentioned indicates the IEEE Address **********. In the following diagram the IEEE Address is "0000C93CC778".
Appendix B Contact Information • Australia: Fujitsu Australia Limited Tel: +61-2-9776-4555 Fax: +61-2-9776-4556 Address: 2 Julius Avenue (Cnr Delhi Road) North Ryde, Australia N.S.W. 2113 • China: Fujitsu (China) Holdings Co., Ltd. Tel: +86-21-5292-9889 Fax: +86-21-5292-9566 Address: 18F, Citic Square, 1168 West Nanjing Road Shanghai, China 200041 • Hong Kong: Fujitsu Hong Kong Limited Tel: +852-2827-5780 Fax: +852-2827-4724 Address: 10/F.
• Singapore: Fujitsu Asia Pte. Ltd. Tel: +65-6777-6577 Fax: +65-6771-5502 Address: 20, Science Park Road, #03-01 TeleTech Park, Singapore Science Park II, Singapore 117674 • Taiwan: Fujitsu Taiwan Limited Tel: +886-2-2311-2255 Fax: +886-2-2311-2277 Address: 19F, No.39, Section 1, Chung hwa Road Taipei, Taiwan • Thailand: Fujitsu Systems Business (Thailand) Ltd.
PRIMERGY ファイバーチャネル拡張ボード (PG-FCD201) 取扱説明書 4Gbit/s FC I/O Module (PG-FCD201) User’s Guide B7FY-2211-01-00 発行日 発行責任 2007 年 9 月 富士通株式会社 Issued on Issued by September, 2007 FUJITSU LIMITED Printed in Japan ● 本書の内容は、改善のため事前連絡なしに変更することがあります。 ● 本書に記載されたデータの使用に起因する、第三者の特許権およびその他の 権利の侵害については、当社はその責を負いません。 ● 無断転載を禁じます。 ● 落丁、乱丁本は、お取り替えいたします。 • The contents of this manual may be revised without prior notice.
こ のマ ニ ュ アルは再生紙を使用 し 、 リ サイ ク ルに配慮 し て製本 さ れています。 不要にな っ た際は、 回収 ・ リ サイ ク ルに出 し て く だ さ い。