User manual

Chapter 9 Operational Settings
Appendix
Glossary
Introduction
Index
Contents
TOP
136
How to Load
Documents
Configuring the
Scan Settings
How to Use the
Operator Panel
Various Ways to
Scan
Daily Care
Troubleshooting
Replacing the
Consumables
Scanner
Overview
Operational
Settings
*1: Depending on the "PART NO." on the product label, the factory default setting differs as follows:
For details about product labels, refer to "8.5 Checking the Product Labels" (page 126).
Item Description Parameter/Value Factory Default
Sheet count Check the counters to determine when to replace
the consumables.
Also use it to reset the counters after replacing the
consumables.
Total Page Count (ADF) / Pad / Pick Roller 0
Power saving Specify the waiting time before entering power
saving mode.
Setting range: 5 to 235 min. (in steps of 5 min.) 15 min.
Power off after a certain period of time: Select to have
the scanner turn off automatically when it is turned on
and left unused for a certain period of time. Also,
specify the time until power-off.
[Power off after a certain period of time] check box (*1)
1 Hour/2 Hours/4 Hours/8 Hours
(when the above check box is selected)
Offset Setting Adjust the position to start the scan on the selected
scanning side(s).
Unit: ADF(Front) / ADF(Back)
Main/Sub/End of page: -2 to +2 mm
(in increments of 0.5)
Main/Sub/
End of page: 0
mm
Vertical magnification
Adjustment
Adjust the magnification level in feed direction for
the selected scanning method.
Unit: ADF
Range: -3.1 to 3.1% (in increments of 0.1)
0%
PART NO. Default
PAxxxxx-Bxx1 Selected / 4 Hours
PAxxxxx-Bxx2 /Bxx3 /Bxx5 /Bxx7 Not selected