Owner's manual
  Operational Amplifier Version 1.0 
Chapter 2 Amplifier Overview 
2 Amplifier Overview Amplifier Overview 
The operational amplifier can be used to sense the ground current, and support front-end 
analog signal conditioning prior to A/D conversion. It can operate in either closed loop mode or 
standalone open loop mode. 
The operational amplifier can be used to sense the ground current, and support front-end 
analog signal conditioning prior to A/D conversion. It can operate in either closed loop mode or 
standalone open loop mode. 
■  Closed Loop Mode ■  Closed Loop Mode 
The operational amplifier can be configured as a non-inverting closed loop operational 
amplifier. 
The operational amplifier can be configured as a non-inverting closed loop operational 
amplifier. 
It has six software-selectable closed loop gain options for ground current sensing according to 
different sense voltage values. 
It has six software-selectable closed loop gain options for ground current sensing according to 
different sense voltage values. 
■  Standalone Open Loop Mode 
In this mode, the operational amplifier input pins are connected to external signals without any 
output feedback. 
The standalone open loop mode is designed for users that can choose more flexible gain using 
external resistors. 
MCU-AN-500080-E-10- Page 5 