Datasheet

1.7 Extended Link Service
C141-C008 1-63
The drive responds with LS_RJT(03h, 1Fh) when this field is any value other
than the above.
(3) Link Error Status Block [PL:W01-06]
This field is used by ACC of the drive.
Individual ERRORS are counted in each Port respectively.
a) Link Failure Count [PL:W01]
The drive counts the number of times when synchronization is not
achieved for a minimum of R_T_TOV (100ms) and enters it in this field.
b) Loss of Synchronization Count [PL:W02]
The drive counts the number of times when loss of synchronization is
detected and enters it in this field.
c) Loss of Signal Count (PL:W03)
The drive does not support this field and responds with all zeros.
d) Primitive Sequence Protocol Error (PL:W04)
The drive does not support this field and responds with all zeros.
e) Invalid Transmission Word (PL:W05)
The drive counts the number of times when Invalid transmission word is
detected and enters it in this field.
f) Invalid CRC Count [PL:W06]
The drive counts the number of times when Data Frame has CRC
ERROR is detected and enters it in this field.