Datasheet

5.2 INIT Error Recovery Methods (Recommended)
C141-C008 5-19
Table 5.5 Sense data error classification (3/3)
K* C* Q* Outline of Error L*
Recovery Method
(See Table 5.6.)
6 29 xx Power on, reset, or BUS DEVICE RESET occurred None 14
The IDD was initialized by a Power on, RESET condition
or BUS DEVICE RESET message.
6 2A 01 Mode parameters changed None 21
The MODE SELECT parameters were changed by
another INIT.
6 2F 00 Commands cleared by another INIT None 25
Commands were cleared by another INIT.
6 3F 01 Microcode has been changed None 27
02 Changed operation definition
7 27 00 Write
p
rotected None 15
Access to a read protected or write protected.
B 03 xx Peripheral device write fault Need 12
11 xx Unrecovered read error
13 xx Sync byte not found for data field
14 xx Record not found
15 xx Mechanical positioning error
B 1B 00 Synchronous data transfer error offset
43 00 Message error Need 6
44 9D SPC detected Sync offset error interrupt.
45 80 Select/Reselect failure
47 00 SCSI parity error
48 00 INITIATOR DETECTED ERROR message received
49 00 Invalid message error
An unrecoverable SCSI related error occurred in the
command execution sequence.
B 4E 00 Overlapped commands attempted None 2
Before execution of a command was completed, a new
command was issued by the same INIT.
4D nn Tagged overlapped commands
E 1D 00 Miscompare during verify operation None 24
Data failed to match in the Byte check mode of the
Verify command.
* K: Sense Key C: Additional Sense Code
Q: Additional Sense Code Qualifier L: Logging Necessary? (shown in Section 5.2.3)