Datasheet
Sense Data and Error Recovery Methods
5-12 C141-C008
Table 5.4 Additional Sense Code and Additional Sense Code Qualifier (6/6)
C* Q* Name Explanation
Sense
key
4E 00 Overlapped commands
attempted
1) Before execution of an untagged command was completed,
the same INIT issued a new command to the same LUN.
2) Before execution of a tagged command was completed, the
same INIT issued a command to the same LUN with the
same tag. Or, an untagged command was issued when not
in the sense hold state.
B
55 04 Insufficient Registration
Resource
PERSISTENT RESERVATION OUT command is issued from
insufficient device server resource.
5
5D nn SMART predictive failure SMART related sense data
•
12: The read error rate attribute has reached the failure
threshold.
•
14: The frequency of grown defect allocation attribute has
reached the failure threshold.
•
43: The seek error rate attribute has reached the failure
threshold.
•
56: The spin up time attribute has reached the failure
threshold.
•
64: The remaining alternate sector count attribute has
reached the failure threshold.
•
FF: The drive is in test mode.
0, 1, 6
C4 nn Drive Failure A serious error was detected in the drive's control system.
('nn' is a Fujitsu unique code)
•
00: Abnormal Rotation of Spindle Motor
•
01: Any error at Spindle Motor Start
•
30: On track failure
4
* C: Additional Sense Code, Q: Additional Sense Code Qualifier