Datasheet

5.1 Sense Data
C141-C008 5-11
Table 5.4 Additional Sense Code and Additional Sense Code Qualifier (5/6)
C* Q* Name Explanation
Sense
key
44 nn Internal target failure An error was detected in self-diagnosis. ("nn" is a Fujitsu unique
code)
90: Next sector IDD compare error
91: WCS RAM parity error
92: Unexpected FMT interrupt
94: NRZ parity error during Write (MAS3*** Series only)
99: Overflow error occurred at SPC FIFO
9A: Unexpected SPC interrupt
9B: SPC detected illegal command interrupt
9C: SPC detected illegal write interrupt
9D: SPC detected Sync offset error interrupt
A0: Error interription from DBM
A3: DBM buffer CRC error
A4: DBM internal parity error
A8: Data late error
B0: Flash ROM erase operation failed.
B1: Flash ROM write operation failed.
C0: RDCLK error (FMT hang up)
D1: DSP downloading failed
D2: DSP overrun (watch dog time out, DRV hard error)
D3: Servo Gate Window error
D4: Illegal error was reported from DSP
4, B
47 00 SCSI parity error A parity error was detected on the SCSI data bus. B
48 00 INITIATOR DETECTED
ERROR message received
The INITIATOR DETECTED ERROR message was received
from the INIT.
B
4C nn Logical unit failed self-
configuration
The IDD's initial setup failed. ('nn' is a Fujitsu unique code)
91: Microcode Read error (any 3/11/** error during
microcode read)
93: Microcode Read error (any 3/13/** NOSB error)
94: Microcode Read error (any 3/14/** NRF error)
95: Microcode Read error (any 3/15/** error during seek)
97: Microcode Read error (any 4/44/** or other errors
during microcode read)
98: Invalid microcode (Header/Check Sum)
A1: SA Read error (any 3/11/** error during SA read)
A3: SA Read error (any 3/13/** error during SA read)
A4: SA Read error (any 3/14/** error during SA read)
A5: SA Read error (any 3/15/** error during SA read)
A7: SA Read error (any 4/44/** error during SA read)
A8: Invalid SA (Header/Check Sum)
A9: SA Read error (DSP downloading failed)
AA: SA Read error (DSP overrun/DRV hardware error)
AB: SA Read error (abnormal rotation of spindle motor)
AC: SA Read error (on-track failure)
E0: Initial calibration failed
4