Datasheet
Sense Data and Error Recovery Methods
5-10 C141-C008
Table 5.4 Additional Sense Code and Additional Sense Code Qualifier (4/6)
C* Q* Name Explanation
Sense
key
00 Medium format corrupted The media format is different from the original format. (The
media was not formatted after the data format specification was
changed by the MODE SELECT command.)
3
31
01 FORMAT command failed For some reason, formatting cannot be completed and
reformatting is necessary.
3
00 No defect spare location
available
No usable alternate block area exists. Or alternate block
processing cannot be performed due to control table overflow.
4 32
01 Defect list update failure Updating of the defect list (G List) failed. 4
01 Unsupported Enclosure
Function
An attempt was made to use a function not supported by the
enclosure service.
5
02 Enclosure Services
Unavailable
The enclosure service currently cannot be used. 2, 4
03 Enclosure Transfer Failure A transfer to or from the enclosure service failed. 4
35
04 Enclosure Transfer Refused An error or incorrect format was detected during a transfer to or
from the enclosure service.
4, 5
37 00 Rounded parameter Rounding processing of the MODE SELECT parameter
specified by the command was performed.
1
03 Logical unit failed Self-Test The test segment error occurred during the Self-Test 4 3E
04 Logical unit unable to update The IDD failed to update the Self-Test result log 4
01 Microcode has been changed Microcode was changed by another INIT. 6
02 Changed operating definition Operating definition was changed. 6
3F
05 Device identifier changed Device identifier was changed. 6
40 nn Diagnostic failure on
component "nn"
An error was detected in self-diagnosis. ("nn" is a Fujitsu
unique code)
• 81: Buffer RAM compare error/bus error
• 82: Program RAM compare error/bus error
• 83: HDC register check error
• 84: Firmware header/check sum error
• 85: Firmware type unmatch
• 86: Parameter header/check sum error
• 88: Drive Serial No. unmatch
• 89: DE type unmatch
• 8F: Other MPU peripheral circuit diagnostic error
• 92: Spindle motor firmware initialize error
4
* C: Additional Sense Code, Q: Additional Sense Code Qualifier