4.4 Maintenance, Diagnostic Commands
C141-C008 4-185
Be sure to set up PCV in 1 when you transfer information on ESI. PCV works
supposing that it is ignored and 00 is set up in the page code even if any page
code is specified when 0 is set up.
Information from Enclosure is transferred to INIT by specifying the above page
code with CDB with the designation of PCV=1 by the following page format.
Remark:
The page code 0x09-0x0F is a reserve in the specification of SES/ESI. It is
issued as an ESI command to Enclosure at present without taking an error
when the 0x09-0x0F is specified in the page code.
When it has the 0x80-0x8F specified, it is issued as Vendor unique Page as
an ESI command to Enclosure.
Table 4.122 ESI page format
Bit
Byte
7 6 5 4 3 2 1 0
0 Page Code
1 0 0 0 0 0 0 0 0
2 Page Parameter Length (MSB)
3 Page Parameter Length (LSB)
4
5 Parameter
n
When it is connected to Enclosure of the SFF-8045 conformity, it is finished with
a “CHECK CONDITION” status (ILLEGAL REQUEST [=5] / Unsupported
Enclosure Function [=35-01]). Short Enclosure Status (Table 4.123) in SFF-8045
form is reported in the case of “SFF-8045” with parallel ESI”.
Table 4.123 Short enclosure status
Bit
Byte
7 6 5 4 3 2 1 0
0 X'08' (Page Code)
1
8045 EFW P_ESI5 P_ESI4 P_ESI3 P_ESI2 P_ESI1 P_ESI0
2 X'00' (Page Parameter Length)
3 X'00' (Page Parameter Length)
~
~
~
~
~
~
Header
Page
parameters