4.4 Maintenance, Diagnostic Commands
C141-C008 4-179
(5) Fault LED test page
Table 4.116 Fault LED test page
Bit
Byte
7 6 5 4 3 2 1 0
0 X ‘A0’ (Page Code)
1 reserved
2 X ‘00’ (Page parameter length)
3 X ‘02’ (Page parameter length)
4 reserved
5 reserved
FLTLED
This page is a page of the Fault LED test
The value of that bit isn’t confirmed with firmware in reserved in the parameter
and the written territory. (Taking usually “0” is recommended.)
This page is to be only for the Send Diagnostic command, and don’t specify this
page with a Receive Diagnostic Results command. And, the movement when it is
specified isn’t assured.
After executing the operation for turning on the Fault LED using this page, be
sure to turn off the Fault LED by executing the operation for turning it off. The
condition of Fault LED isn’t assured when download of Firmware and Reset from
the interface are carried out with turning it on.
a. FLTLED bit
1: Fault LED is turned on when ‘1’ is set up to this bit
0: Fault LED turns off the lights when ‘0’ is set up to this bit