Datasheet
Command Specifications
4-162 C141-C008
If this command is terminated with a CHECK CONDITION status,
the sense code/sub-sense code in the sense data is other than “No
defect spare location available [=32-00], and a valid logical block
address (other than X ‘FFFFFFFF’) is displayed in the “Command
inherent information” field, it is necessary for the INIT to reissue
this command by the following procedure after executing recovery
processing (shown in Section 5.2) in accordance with the contents
of the sense data.
1. Delete the defect descriptors which precede the defect
descriptor that specifies the logical block address displayed in
the “Command inherent information” field of the sense data
from the defect descriptor list specified in this command, and
leave that defect descriptor in the list.
Logical block address that indicates the “Command inherent
information” field of the sense data.
XXXX
Defect Descriptor List
Delete
Figure 4.4 Correction of the defect descriptor
2. Change the “Defect List Length” in the header and add the new ”Defect
descriptor list” corrected in 1), then reissue the REASSIGN BLOCKS
command.