4.1 Control/Sense Commands
C141-C008 4-91
CHAPTER 4 Comman d Specif icatio ns
4.1 Cont rol/ Sense Com mands
Table 4.38 PC (page control)
Value Description
00b
01b
10b
11b
Current threshold values
Current cumulative values
Default threshold values
Default cumulative values
The "PC" bits are ignored by the drive. The drive assumes that current cumulative
parameters are selected.
The "Parameter List Length" field specifies the length in bytes of the parameter list
that is located in the Data-Out Buffer. If a parameter list length results in the truncation
of any log parameter, the device server terminates this command with CHECK
CONDITION status (ILLEGAL REQUEST [=5] / Invalid field in CDB [=24-00]).
A "Parameter List Length" of zero indicates that no pages shall be transferred.
This condition shall not be considered an error.
The IDD does not support that the application client should send
pages in ascending order by page code value if the Data-Out Buffer
contains multiple pages.
Table 4.39 LOG SELECT command parameter configuration
Bit
Byte
7 6 5 4 3 2 1 0
0 Page Code
1 Reserved
2 Page Length (MSB)
3 Page Length (LSB)
4
x+3
Log Parameter (First)
(Length x)
n-y+1
Log Parameter (Last)
(Length y)
n
Header
~
~
~
~
~
~
~ ~
~
~ ~
~
Log
Paramete