Datasheet

4.1 Control/Sense Commands
C141-C008 4-63
The "Report Count" field indicates the number of timer to report an
informational exception conditions to the application client.
A value of zero in the Report Count field indicates there is no limit on the
number of timers the target shall report an information exception condition.
(10) Fibre channel control parameters (page code = 19)
Table 4.29 MODE SELECT parameters: fibre channel control parameters
Bit
Byte
7 6 5 4 3 2 1 0
0 PS* 0 0 1 1 0 0 1
1 X‘0E’ (Page Length)
2 X‘00’ (Reserved)
3 DTFD PLPB DDIS DLM RHA ALWLI DTIPE DTOLI
Default 0 0 0 0 0 0 0 0
Variable 1 1 1 1 1 1 1 1
4 X‘00’ (Reserved)
5 X‘00’ (Reserved)
6 RR_TOV Units
Default 0 0 0 0 0 0 1 1
Variable 0 0 0 0 0 0 0 0
7 RR_TOV Value
Default X‘14’
Variable X‘00
8 CONTROL_MCM
Default 0 0 0 0 0 0 0 1
Variable 0 0 0 0 0 0 0 0
9 X‘00’ (Reserved)
10 X‘00’ (Reserved)
11 ORIGINATOR CMR
Default X‘00’
Variable X‘00
12 X‘00’ (Reserved)
13 RESPONDER CMR
Default X‘00’
Variable X‘00
14-15 MCM Timeout Value
Default X‘0000’
Variable X‘0000’