Datasheet

4.1 Control/Sense Commands
C141-C008 4-37
The IDD disregards the value specified in this parameter and operates in
accordance with the default value (00).
h. EMDP (enable modify data pointer) (not supported)
This bit indicates whether or not the initiator allows the data transfer to be re-
ordered by the target.
The IDD are not supported a MODIFY DATA POINTER message.
Therefore, The IDD disregards the value specified in this bit, and operates
according to the "Default" value.
"0" : The IDD cannot transfer a MODIFY DATA POINTER message.
"1" : The IDD can transfer a MODIFY DATA POINTER message.
i. FARd, FAWrt, FAStat (fair arbitration read/write/status)
When connected is requested for Read, Write or Status transfers, this
specifies whether Arbitration Fairness Control is enabled or disabled.
The IDD disregards the value specified in this parameter and operates in
accordance with the default value.
j. Dlmm (disconnect immediate) (not supported)
This controls when to execute Loop CLOSE after receiving the frame. The
IDD does not support this bit. If 1 is specified in this bit, the command is
terminated with the "CHECK CONDITION" status.
k. Burst size during the initial connection
This parameter specifies the maximum data volume that can be transferred in
the connected state when the TARG receives a command as a multiple of 512
bytes.
The IDD disregards the value specified in this parameter and operates in
accordance with the default value (0000 = unlimited).