Datasheet

Command Specifications
4-34 C141-C008
(2) Disconnect/reconnect parameters (page code = 2)
The format of the page descriptor in this MODE SELECT parameter is shown in
Table 4.16.
Table 4.16 MODE SELECT parameters: disconnect/reconnect parameters
Bit
Byte
7 6 5 4 3 2 1 0
0 0 0 0 0 0 0 1 0
1 X‘0E’ or X‘0A’ (Page Length)
2 Buffer Full Ratio
Default X‘00’
Variable X‘FF’
3 Buffer Empty Ratio
Default X‘00’
Variable X‘FF’
4-5 Bus Inactivity Limit
Default X‘0000’
Variable X‘0000’
6-7 Disconnect Time Limit
Default X‘0000’
Variable X‘0000’
8-9 Connect Time Limit
Default X‘0000’
Variable X‘0000’
10-11 Maximum Burst Size
Default X‘0100’
Variable X‘0000’
12 EMDP FARd FAWrt FAStat DImm DTDC
Default 0 1 1 1 0 0 0 0
Variable 0 0 0 0 0 0 0 0
13 X‘00’
14-15 (Burst Size During the Initialize Connection)
Default X‘0000’
Variable X‘0000’