Datasheet

Command Specifications
4-26 C141-C008
If transfer of this page descriptor is requested by the MODE SENSE
or MODE SENSE EXTENDED command, the IDD reports X '0A'
as the page length (byte 1). However, if either X '0A' or X '06' is
specified for the page length in the MODE SELECT or MODE
SELECT EXTENDED command, the IDD treats it as though the
correct page length was specified. If X '06' is specified for the page
length, the value specified in the "Number of retries during READ"
field is used as is in the "Number of retries during WRITE" field
and the value specified in the "Number of retries during READ"
field is also used as is in the "Number of retries during VERIFY"
field. The X '06' page length is included in consideration of
compatibility with previous models, but as much as possible, it is
recommended that the INIT use the X '0A' page length.
Error recovery parameters defined in this page descriptor are applicable for the
following commands, except in cases where it is specifically pointed out.
READ
READ EXTENDED
READ LONG
SEND DIAGNOSTIC (Write/read test)
WRITE
WRITE AND VERIFY (Write operation)
WRITE EXTENDED
WRITE LONG
a. AWRE (automatic write reallocation enabled)
"1": An "automatic alternate block allocation processing" operation is
specified during execution of a write operation.
"0": An "automatic alternate block allocation processing" operation is
prohibited during execution of a write operation.
Automatic alternate block allocation processing is explained in Section 5.3.2.
b. ARRE (automatic read reallocation enable)
"1": An "automatic alternate block allocation processing" operation is
specified during execution of a read operation.
"0": An "automatic alternate block allocation processing" operation is
prohibited during execution of a read operation.
Automatic alternate block allocation processing is explained in Section 5.3.2.